K-7
E6581531
11
[4] Terminal response time setup
Sensorless vector/vector with sensor (
●
:Effective, -:Ineffective)
Default setting
Title
Communication
No.
Function Adjustment
range
Minimum
setting unit
(Panel/Communi
cation)
V[R
=
500V
-50Hz
V[R
=
575V
-60Hz
V[R
=
690V
-50Hz
Write
during
running
Vector
control
V/f
Reference
H
0168
Output terminal function selection 10
(R3) *1
0~255 *2
1/1
254
254
254
Disabled
●
/
●
●
7. 2. 2
H
0169
Output terminal function selection 11
(R4) *1
0~255 *2
1/1
254
254
254
Disabled
●
/
●
●
7. 2. 2
H
0170
Base frequency 2
25.0~
HJ
Hz
0.1/0.01
50.0
60.0
50.0
Disabled
-
●
6. 4. 1
H
0171
Base frequency voltage 2
50~990V
1/0.1
500
575 690
Disabled
-
●
6. 4. 1
H
0172
Manual torque boost 2
0.0~30.0%
0.1/0.1
*3 *3 *3
Enabled
-
●
6. 4. 1
H
0173
Thermal protection level 2
10~100% 1/1
100
100 100
Enabled
-
●
6. 4. 1
*1: Unsupported option
*2:
⇒
For the adjustment range, see the table on page K-44.
*3: Default values vary depending on the capacity.
⇒
See the table of K-47.
[5] V/f 5-point setting
Sensorless vector/vector with sensor (
●
:Effective, -:Ineffective)
Default setting
Title
Communication
No.
Function Adjustment
range
Minimum
setting unit
(Panel/Communi
cation)
V[R
=
500V
-50Hz
V[R
=
575V
-60Hz
V[R
=
690V
-50Hz
Write
during
running
Vector
control
V/f
Reference
H
0190
V/f 5-point setting VF1 frequency
0.0~
HJ
Hz
0.1/0.01
0.0 0.0 0.0
Disabled
-
●
5. 6
H
0191
V/f 5-point setting VF1 voltage
0.0~100.0%
0.1/0.01
0.0 0.0 0.0
Disabled
-
●
5. 6
H
0192
V/f 5-point setting VF2 frequency
0.0~
HJ
Hz
0.1/0.01
0.0 0.0 0.0
Disabled
-
●
5. 6
H
0193
V/f 5-point setting VF2 voltage
0.0~100.0%
0.1/0.01
0.0 0.0 0.0
Disabled
-
●
5. 6
H
0194
V/f 5-point setting VF3 frequency
0.0~
HJ
Hz
0.1/0.01
0.0 0.0 0.0
Disabled
-
●
5. 6
H
0195
V/f 5-point setting VF3 voltage
0.0~100.0%
0.1/0.01
0.0 0.0 0.0
Disabled
-
●
5. 6
H
0196
V/f 5-point setting VF4 frequency
0.0~
HJ
Hz
0.1/0.01
0.0 0.0 0.0
Disabled
-
●
5. 6
H
0197
V/f 5-point setting VF4 voltage
0.0~100.0%
0.1/0.01
0.0 0.0 0.0
Disabled
-
●
5. 6
H
0198
V/f 5-point setting VF5 frequency
0.0~
HJ
Hz
0.1/0.01
0.0 0.0 0.0
Disabled
-
●
5. 6
H
0199
V/f 5-point setting VF5 voltage
0.0~100.0%
0.1/0.01
0.0 0.0 0.0
Disabled
-
●
5. 6
[6] Speed/torque reference gain/bias setup [1/3]
Sensorless vector/vector with sensor (
●
:Effective, -:Ineffective)
Default setting
Title
Communication
No.
Function Adjustment
range
Minimum
setting unit
(Panel/Communi
cation)
V[R
=
500V
-50Hz
V[R
=
575V
-60Hz
V[R
=
690V
-50Hz
Write
during
running
Vector
control
V/f
Reference
H
0200
Frequency priority selection
0:
HOQF
/
H
terminal switching (input
terminal function selection 104, 105)
1:
HOQF
/
H
frequency switching
(switching with
H
)
1/1
0 0 0
Enabled
●
/
●
●
6. 6. 1
H
0201
VI/II input point 1 setting
0~100%
1/1
0 0 0
Enabled
●
/
●
●
7. 3. 2
H
0202
VI/II input point 1 frequency
0.0~
HJ
Hz
0.1/0.01
0.0 0.0 0.0
Enabled
●
/
●
●
7. 3. 2