E6581531
J-9
10
10.5
Optional internal devices
Here are the internal devices optionally available. There are two types of optional devices: Add-on type and Plug-in type.
Table of optional devices
Option name
Function, purpose
Model
Type of
installation
(1) Expansion I/O card1
(Logic input/ PTC input)
ETB003Z Add-on
Exp
a
ns
io
n
termi
na
l
func
tion
(2) Expansion I/O card2
(Function of the above optional card 1
+ Analogue input/ Pulse input)
Used to extend input and output
terminals.
ETB004Z Add-on
(3) CC-Link communication card
Used to connect to a CC-Link
network for control.
CCL001Z Add-on
(4) DeviceNet communication card
Used to connect to a DeviceNet
network for control.
DEV002Z Add-on
(5) PROFIBUS-DP communication card
Used to connect to a
PROFIBUS-DP network for control.
PDP002Z Add-on
(6) L
ON
W
ORKS
communication card
Used to connect to a L
ON
W
ORKS
network for control.
LIU006Z Add-on
(7) BAC net communication card
Used to connect to a BAC net
network for control.
BCN001Z Add-on
(8) Metasys N2 communication card
Used to connect to a Metasys N2
network for control.
MTS001Z Add-on
Co
m
m
u
n
ica
tio
n
fu
n
ct
io
n
(9) APOGEE FLN communication card
Used to connect to a APOGEE FLN
network for control.
APG001Z Add-on
(10) PG feedback option
(Push-pull 12V)
VEC004Z Plug-in
(11) PG feedback option
(Push-pull 15V)
VEC005Z Plug-in
(12) PG feedback option
(Push-pull 24V)
VEC006Z Plug-in
Othe
r func
tion
(13) PG feedback option
(RS422-5V)
Used to issue motor pulse train rate
commands or used for sensor
vector control.
VEC007Z Plug-in
Functions of Add-on type options
(1) Expansion I/O card1 option (Logic input/ PTC input)
Function Description
Multifunction programmable contact
input (4 points)
No-voltage contact input (24Vdc-5mA or less)
Sink logic input (at a common voltage of 24V)
Source logic input
ON: Less than 10Vdc
ON: 11Vdc or more
OFF: 16Vdc or more
OFF: Less than 5Vdc
Multifunction programmable open
collector output (2 points)
Driving current: Max. 50mA when an external power source is used
Max. 20mA when the internal power source is used
Driving voltage: 12V (min) to 30V (max)
Multifunction programmable relay
contact output
1C contact configuration
250Vac-2A (cos
φ
=1), 250Vac-1A (cos
φ
=0.4), 30Vdc-1A
External thermal trip input
Resistance between TH+ and TH-
Error: Approx. 70
Ω
or less or approx. 3k
Ω
or more
Recovery from error: Approx. 1.6k
Ω
24V power output
24Vdc - 60mA max
-10V power output
-10Vdc -10mA
Contact input common terminal
Common terminals for contact input