[22] Protection functions [3/3]
Sensorless vector/vector with sensor (
●
:Effective, -:Ineffective)
Default setting
Title
Communication
No.
Function Adjustment
range
Minimum
setting unit
(Panel/Communi
cation)
V[R
=
500V
-50Hz
V[R
=
575V
-60Hz
V[R
=
690V
-50Hz
Write
during
running
Vector
control
V/f
Constant
Reference
H
0647
Control power supply backup option
failure monitoring
0:Control power supply not backed up
1:Control power supply backed up (alarm in the
event of a failure)
2:Control power supply backed up (tripping in
the event of a failure)
1/1
0 0 0
Disabled
●
/
●
●
6. 26. 24
H
0650
Forced fire-speed control selection
0:Disabled, 1:Enabled
1/1
0 0 0
Enabled
●
/
●
●
6.
27
H
0651
Undertorque detection selection
0:Alarm mode, 1:Trip mode
1/1
0 0 0
Enabled
●
/
●
●
6.
28
H
0652
Undertorque detection level during
power running
0~250% 1/0.01
0 0 0
Enabled
●
/
●
●
6.
28
H
0653
Undertorque detection level during
regenerative braking
0~250% 1/0.01
0 0 0
Enabled
●
/
●
●
6.
28
H
0654
Undertorque detection time
0.00~10.00 sec.
0.01/0.01
0.50
0.50
0.50
Enabled
●
/
●
●
6.
28
H
0655
Undertorque detection hysteresis
0~100%
1/0.01
10
10
10
Enabled
●
/
●
●
6.
28
Содержание TOSVERT VF-PS1