11
[Monitor FM/AM/pulse output function selection (2/3)]
Sensorless vector/vector with sensor (
●
: valid, -: invalid)
FM/AM/pulse output
Monitor output
Option No. Communicati
on No.
Option No.
Communicati
on No.
Function
Unit
(Communicat
ion)
Trip
retention
Vector
control
V/f Reference
- -
33
FE67
Attached to expansion I/O card 2 CPU version
- ×
●
/
●
●
34
FE76
34
FE76
Integral input power
Depends on
H
×
●
/
●
●
35
FE77
35
FE77
Integral output power
Depends on
H
×
●
/
●
●
45
0006 *3
0671 *4
- -
Gain
display
1
-
●
/
●
●
46
FE60
-
-
My function monitor 1 (Output of unsigned value)
1
×
●
/
●
●
47
FE61
-
-
My function monitor 2 (Output of unsigned value)
1
×
●
/
●
●
48
FE62
-
-
My function monitor 3 (Output of signed value) *2
1
×
●
/
●
●
49
FE63
-
-
My function monitor 4 (Output of signed value) *2
1
×
●
/
●
●
50
FD00
50
FE00
Signed output frequency *5
0.01Hz
○
●
/
●
●
51
FD02
51
FE02
Signed frequency command value *5
0.01Hz
○
●
/
●
●
52
FD15
52
FE15
Signed compensated frequency *5
0.01Hz
○
●
/
●
●
53 FD16
53
FE16
Signed speed feedback (real-time value)*5
0.01Hz
○
-/
●
-
54 FD17
54
FE17
Signed speed feedback (1-second filter) *5
0.01Hz
○
-/
●
-
55 FD18
55
FE18
Signed
torque
*5
0.01%
○
●
/
●
●
*1
56
FD19
56
FE19
Signed torque command *5
0.01%
○
- -
58 FD20
58
FE20
Signed
torque
current
0.01%
○
●
/
●
●
*1
59
FD22
59
FE22
Signed PID feedback value *5
0.01
○
●
/
●
●
60
FE37
60
FE37
Signed RX input *5
0.01%
×
●
/
●
●
61
FE38
61
FE38
Signed optional AI1 input *5
0.01%
×
●
/
●
●
62
FE51
-
-
Signed fixed output 1
-
×
●
/
●
●
63
FE50
-
-
Signed fixed output 2
-
×
●
/
●
●
64
FE52
-
-
Signed fixed output 3
-
×
●
/
●
●
5.16
8.3
*1: Reference data *2: An absolute value is output for pulse train output of 48 and 49.
*3: Communication no. for FM output *4: Communication no. for AM output
*5: If a negative value is specified, the negative sign “-” is displayed.
The negative sign “-” is affixed only to values displayed on the monitor. Keep in mind that no sign is affixed to any values read
through a communications device.
⇒
For details, refer to Section 5.16; [Terminal FM-related parameters].
⇒
For monitor indications, refer to Section 8.3; [Set up values of monitor indication parameters].
Содержание TOSVERT VF-PS1
Страница 1: ......
Страница 19: ...E6581531 A 7 1 VFPS1 6370PL 6900PL VFPS1 6110KPC 6200KPC ...
Страница 20: ...E6581531 A 8 1 VFPS1 6250KPC 6400KPC VFPS1 6500KPC 6630KPC ...
Страница 30: ...E6581531 A 18 1 VFPS1 6250KPC 6315KPC 6400KPC VFPS1 6500KPC 6630KPC ...
Страница 317: ......