K-20
E6581531
11
[22] Protection functions [2/3]
Sensorless vector/vector with sensor (
●
:Effective, -:Ineffective)
Default setting
Title
Communication
No.
Function Adjustment
range
Minimum
setting unit
(Panel/Communi
cation)
V[R
=
500V
-50Hz
V[R
=
575V
-60Hz
V[R
=
690V
-50Hz
Write
during
running
Vector
control
V/f
Constant
Reference
H
0623
Overspeed detection frequency upper band 0.0:Disabled, 0.1~30.0Hz
0.1/0.01
0.0 0.0 0.0
Enabled
-/
●
-
6. 26. 13
H
0624
Overspeed detection frequency lower band 0.0:Disabled, 0.1~30.0Hz
0.1/0.01
0.0 0.0 0.0
Enabled
-/
●
-
6. 26. 13
H
0625
Undervoltage detection level
50~79% for 500V class
44~70% for 575V class
37~59% for 690V class, 80: (auto mode)
1/1
66 66 59
Disabled
●
/
●
●
6. 26. 15
H
0626
Overvoltage limit operation level
100~150%
1/1
*2 *2 *2
Disabled
●
/
●
●
6. 15. 2
H
0627
Undervoltage trip selection
0:Disabled, 1:Enabled
1/1
0 0 0
Disabled
●
/
●
●
6. 26. 15
H
0629
Regenerative power ride-through control level
55~100% for 500V class
49~100% for 575V class
42~100% for 690V class
1/1 55
49 42
Disabled
●
/
●
●
6. 26. 16
H
0631 Temperature
detection
0:Standard (120%-60 sec.)
1:Estimation of temperature
1/1
0 0 0
Disabled
- - 5.
14
H
0633
VI/II analog input wire breakage
detection level
0:None
1~100%
1/1
0 0 0
Enabled
●
/
●
●
6. 26. 17
H
0634
Annual average ambient temperature
(calculation for part replacement alarms)
1:-10~+10°C
2:+11~+20°C
3:+21~+30°C
4:+31~+40°C
5:+41~+50°C
6:+51~+60°C
1/1
3 3 3
Enabled
●
/
●
●
6. 26. 18
H
0635
Rush current suppression relay
activation time
0.0~2.5 sec.
0.1/0.1
0.0 0.0 0.0
Disabled
●
/
●
●
6. 26. 19
H
0637 PTC1
thermal
selection
0:Deselect,
1:Select
1/1 0 0 0
Disabled
●
/
●
●
*1
H
0638 PTC2
thermal
selection
0:Deselect,
1:Select
1/1 0 0 0
Disabled
●
/
●
●
*1
H
0639
Braking resistance overload time (10
times of rated torque)
0.1~600.0 sec.
0.1/0.1
5.0 5.0 5.0
Disabled
●
/
●
●
5.
19
H
0640
Step-out detection current level
10~150
1/1
100 100 100
Disabled
- - 6.
24
H
0641
Step-out detection time
0.0:Not detect, 0.1~25.0
0.1/0.1
0.0 0.0 0.0
Disabled
- - 6.
24
H
0643
Brake-equipped motor restart condition
selection
0:Default (no waiting time for frequencies of
10Hz and less)
1:Conditional (no waiting time for frequencies
of 20Hz and less)
1/1
0 0 0
Disabled
●
/
●
●
6. 26. 22
H
0644
Action in the event of VI/II analog input
wire breakage
0:Trip mode
1: The inverter operates the motor at preset
speed operation frequency 14.
1/1
0 0 0
Disabled
●
/
●
●
6. 26. 17
H
0645 PTC
thermal
selection
0:Disabled
1:Enabled (trip mode)
2:Enabled (alarm mode)
1/1
0 0 0
Disabled
●
/
●
●
6. 26. 23
H
0646
PTC detection resistor value
100-9999
Ω
1/1
3000
3000
3000 Disabled
●
/
●
●
6. 26. 23
*1:
⇒
For details, refer to Instruction Manual (E6581339) specified in Section 6.36.
*2: Default values vary depending on the voltage range.
⇒
See the table on page K-47.