E6581531
F-39
6
6.20
Increasing the motor output torque further in low speed range
H
: Exciting strengthening coefficient
H
: Stall prevention factor
The output torque of the motor can adjusted using the parameters described in 6.19 in most cases, but if a finer
adjustment is required, use these parameters.
[Parameter setting]
Title
Function
Adjustment range
Default setting
H
Exciting strengthening coefficient
~
%
H
Stall prevention factor
~
If the torque needs to be increased in low speed range (10Hz or less as a guide)
Perform auto-tuning according to the instructions in 6.19, and if the torque needs to be increased further in low speed
range, first increase the slip frequency gain (
H
) to a degree (80% or so as a guide) that hunting of the motor
does not occur. Then, increase motor constant 1 (
H
) by 1.1 times the current value as a guide. If the torque
needs to be increased even further, increase the exciting current factor (
H
) to a maximum of 130%.
H
is
a parameter that increases the magnetic flux of the motor at low speeds, so specifying a higher value for
H
increases the no-load current. If the no-load current exceeds the rated current, do not adjust this parameter.
If the motor stalls when operated at frequencies above the base frequency
Adjust
H
(stall prevention factor).
If a heavy load is applied momentarily (transiently), the motor may stall before the load current reaches the stall
prevention level (
H
). In such a case, a motor stall may be avoided by reducing the value of
H
gradually.