Series 2268 850 Watt DC Power Supplies Reference Manual
Analog Programming & Isolated Analog Programming
2268S-901-01 Rev. A / January 2015
85
Query for Analog Current Input Level
To query for analog current input level from non-isolated input:
1.
Turn the 9-position mode control to the CAP position or press the rotary
Adjust/Enter control if the mode control is already at the CAP position.
is displayed on the output voltage display.
2.
If the mode is currently
then select any other APG mode. If this step is done,
be sure to restore the APG setting to
when the operation is complete.
Otherwise, do not rotate the rotary Adjust/ Enter control to keep the current APG
mode.
3.
Press the rotary Adjust/Enter control to select the APG mode.
The output voltage display should read
and the output current display will display
APG level.
4.
Press the rotary Adjust/Enter control to return to normal mode.
5.
If the APG mode was modified in step 2, execute the procedure to deactivate the
APG voltage mode.
Quick Tip: Remote
Operation uses these
SCPI commands. See
page 101.
The SCPI commands for these instructions are:
[:]SYSTem[<channel>]:REMote:SOURce:CURRent <?|LOCal
|AVOLtage|IAVoltage|ARESistive|IAResistive>
[:]SYSTem[<channel>]:COMMunicate:APRogram:LEVel:CURRent [:ISOLated]
[:]MEASure[<channel>][:SCALar]:APRogram:CURRent[:DC]?