Local Operation
Series 2268 850 Watt DC Power Supplies Reference Manual
60
2268S-901-01 Rev. A / January 2015
Recalling User Setting Memory Locations
This feature recalls settings that were previously saved.
To load user setting memory locations:
1.
Turn the 9-position mode control to the RCL position.
is displayed on the output voltage display with a number indicating a preset position
on the output current display.
2.
Turn the rotary Adjust/Enter control to select a preset position from 1 to 3.
3.
Press the rotary Adjust/Enter control.
is displayed on the output voltage display.
The settings in the selected user setting memory locations have now been applied to the
power supply.
The SCPI command (s) for these instructions are:
*RCL <setting_location>
or
[:]SYSTem[<channel>]:RECall <setting_location>
Three user setting memory locations are available and one user setting memory location
is saved automatically before AC power shutdown. This user setting memory location
will be loaded after AC power is restored.