Remote Operation
Series 2268 850 Watt DC Power Supplies Reference Manual
124
2268S-901-01 Rev. A / January 2015
Multichannel Commands Explained
The use of multichannel addressing allows you to send messages to one device, more than
one device or to all devices. Any of the remote interface types can be used to send a
multichannel command through the device that is physically connected to the PC to all the
devices, provided that all other devices are connected to via the RS-485 bus. In order to use
multichannel addressing, the setup of the wiring should be completed as described in
“Multiple Power Supply Connections to RS-485 Bus” on page 117.
All SCPI commands in the power supply support the use of multichannel addressing;
however, only one device can respond to a message. Responses will be sent according to the
conditions defined below.
Rules for Multichannel Responses
Condition
Response
Example
No multichannel
address used
Only the device selected using the
*adr
or
:SYST[<address>]
:COMM[:MCH]:ADDR
commands
will respond.
SYSTem:VERSion?
Single multichannel
address specified
The device addressed in the command
will respond regardless of if it has been
selected.
SYSTem2:VERSion?
ALL or broadcast
multichannel
address specified
Only the device selected using the *adr
or
:SYST[<channel>]:C
OMM[:MCH]:ADDR
commands will
respond. If none of the devices have
been selected then no response will be
seen.
:SYSTem
ALL:VERSion?
or
:SYSTem0:VERSion?
Multiple
multichannel
addresses specified
Only the device selected using the
*adr
or
:SYST[<address>]
:COMM[:MCH]:ADDR
commands will
respond. If none of the devices have
been selected then no response will be
seen.
SYSTem
1,2,4,5,6:VERSion?