Series 2268 850 Watt DC Power Supplies Reference Manual
LAN/Ethernet Setup and Communication
2268S-901-01 Rev. A / January 2015
181
Click
Input/Output
to begin communicating with the unit.
Verify after every command sent that you are also using the correct termination
character which in this case is
\r.
Figure 72: Verifying Correct Termination Character
Before starting communicating with the power supply, you need to first set the address
from what you set the unit to via front panel controls using the command
*ADR
N
where
N
is the address #. For example, if the unit address was set to 1, send the command
*ADR 1
.
Then send an identification query to the unit using
*IDN?
to verify communication.
Your response should be the identification string of the unit.