Local Operation
Series 2268 850 Watt DC Power Supplies Reference Manual
66
2268S-901-01 Rev. A / January 2015
Connecting to the Load in Remote Sensing Mode
Connect the negative (-) output terminal of one power supply to the positive (+) output
terminal of the next power supply. The more positive supply's positive sense line should
connect to the positive terminal of the load (or distribution point). Its return sense line
should connect to the connection between the two units at the same spot as the negative
supply's positive sense line. The return sense line of the negative supply should be
connected to the return of the load. See Figure 16.
CAUTION: Equipment damage
Do not connect sense lines through relays.
Figure 16: Load Connections in Remote Sensing Mode