D 13373.08
NOVEMBER 2007
MPS
TANDBERG
MPS
ADMINISTRATOR GUIDE
Conference Template
Conference Template Configuration
The Conference Templates are found in the MCU Configuration tab.
The predefined settings will be used as default settings when creating
new conferences based on this specific template. TANDBERG MPS
enables the setup of 10 different conference templates.
The conference template contains the same settings as de-
scribed in the
in the Overview section.
Conference Template Configuration
Participants Settings
Video Participant Limit
Defines the maximum number of Video Participants allowed in the
conference and reserves the number of needed
ports for this conference.
Values: 0 - 40 for MPS 200 and 0 - 160 for MPS 800.
Telephone Participant Limit
Defines the maximum number of Telephone Participants allowed in
the conference.
Values: 0 - 32 for MPS 200 and 0 - 48 for MPS 800.
Welcome Picture and Sound
On:
When set to On a Welcome screen and audio message will be
shown to each new participant of the conference.
Off:
Set to Off to disable the Welcome screen and audio message.
Entry and Exit Tone
On:
When set to On a tone signal will be heard each time a participant
is entering or leaving the conference.
Off:
Set to Off to disable the Entry and Exit Tone.
Timeout Participants from Call List
On:
When set to On all participants that has been disconnected from
the conference will be cleared from the Call List within 2 minutes.
Off:
Set to Off to disable the Timeout Participants from Call List.
Press
Save
to activate the new settings