5
14
9
5
11,5 Non-linearity
6
20
10
10
15
Damage!
4.1.6.2.3 Temperature Sensor input
In the Circulo products family, a dedicated temperature port is available which is directly connected to the
ADC input and has a high input resistance. On this port the resistance of a temperature sensor can be
measured with high accuracy.
Note
It is recommended to use the temperature input port only for measuring temperature with an RTD
temperature sensor.
The signals are available in different objects, for details, please refer to the hardware manuals of
For details about using temperature sensors please
check our System integration guide on temperature
4.1.6.2.4 Internal Resistance
SOMANET Node and Circulo servo drives support different types of analog inputs. These inputs support a
wide range of industrial sensors, e.g. torque, temperature, position and speed but have different internal
resistance, saturation values and voltage limits.
Synapticon Documentation
© 2021 Synapticon GmbH | Daimlerstraße 26 | D-71101 Schönaich Documentation v 4.19.0 | Built 2022-02-01