3.1.8.2.2.3 Profile torque mode
In profile torque mode, a constant torque is generated according to the target torque and the defined torque
slope (the rate of change of torque).
Output of the generator is the torque demand value (0x6074) which is processed by the torque controller.
3.1.8.2.2.3.1 Objects configuration
The following objects need to be configured for the torque profile:
Quick Stop deceleration 0x6085
Note
is limited by the Object :
Synapticon Documentation
© 2021 Synapticon GmbH | Daimlerstraße 26 | D-71101 Schönaich Documentation v 4.19.0 | Built 2022-02-01
647/1031