Note
Protective Earthing is not required for Extra-Low Voltage Drives.
1.2.2.1.1.2 Connecting a brake
If your system has an attached brake, please connect the brake cables to the brake connector. These two
threads should be twisted together or at least be paired to have a minimum area between them.
Note
This brake integrates Safe Brake Control functionality (SBC).
Attention
The brake output is not short circuit protected. The brake power output may get irreversibly damaged
in case of a short circuit.