3.1.9.1.43 0x2006 Protection
Provides user-defined values for setting protection thresholds. If the measured value of one of these
parameters exceeds the threshold, the drive will issue an error and halt the drive.
Name
Index:Sub Type
Bit
Size
Min
Data
Max
Data
Default
Data
Unit Access
PDO
Mapping
Undervoltage
setpoint
0x2006:1
DINT
32
0
V
readwrite
Custom value for undervoltage protection.
Name
Index:Sub Type
Bit
Size
Min
Data
Max
Data
Default
Data
Unit Access
PDO
Mapping
Overvoltage
setpoint
0x2006:2
DINT
32
1000
V
readwrite
Custom value for overvoltage protection.
Name
Index:Sub Type
Bit
Size
Min
Data
Max
Data
Default
Data
Unit Access
PDO
Mapping
Overcurrent
setpoint
0x2006:3
DINT
32
500000
mA
readwrite
Custom value for overcurrent protection.