1.3.2.1.2.2 Connecting a Brake
Attention
When using a safe brake in combination with Node Safety, use
If your system has an attached brake, please connect the brake cables to Phase D and Ground. These two
threads should be twisted together or at least be paired to have a minimum area between them.
By default, Logic Supply is deactivated, it is therefore recommended to use Logic Ground (pin 7 of the Main
Supply Connector) for the brake.
If Logic Supply is active, Ground of the brake can be connected to the Ground cable of the 48V power supply
in a spot close to the board or it can be connected together with the Ground of the 48V supply to the pin 5 of
the Main Supply connector if they fit in there.
Synapticon Documentation
© 2021 Synapticon GmbH | Daimlerstraße 26 | D-71101 Schönaich Documentation v 4.19.0 | Built 2022-02-01
169/1031