Name
Index:Sub Type
Bit
Size
Min
Data
Max
Data
Default
Data
Unit Access
PDO
Mapping
Constant a3
0x2038:7
REAL
32
0
readwrite
Constant a3 of the polynomial (3rd order coefficient)
Name
Index:Sub Type
Bit
Size
Min
Data
Max
Data
Default
Data
Unit Access
PDO
Mapping
Constant a4
0x2038:8
REAL
32
0
readwrite
Constant a4 of the polynomial (4th order coefficient)
Name
Index:Sub Type
Bit
Size
Min
Data
Max
Data
Default
Data
Unit Access
PDO
Mapping
Constant a5
0x2038:9
REAL
32
0
readwrite
Constant a5 of the polynomial (5th order coefficient)
Name
Index:Sub Type
Bit
Size
Min
Data
Max
Data
Default
Data
Unit Access
PDO
Mapping
Cutoff
frequency
0x2038:10 UINT
16
1
10000
500
Hz
readwrite
Cutoff frequency (Hz) for the LP filter for external scaled analog measurements.
Name
Index:Sub Type
Bit
Size
Min
Data
Max
Data
Default
Data
Unit Access
PDO
Mapping
Upper error
threshold
0x2038:11 REAL
32
1199570688
readwrite
Upper error threshold for the external scaled measurements. When the scaled measurement value
exceeds this threshold, a fault is generated. It is also used to generate a warning when the scaled
measurement value is within 5% of the error threshold.
The default value corresponds to the equivalent int representation of the float value 65535.0
Name
Index:Sub Type
Bit
Size
Min
Data
Max
Data
Default
Data
Unit Access
PDO
Mapping
Lower error
threshold
0x2038:12 REAL
32
0
readwrite
Lower error threshold for the external scaled measurements. When the scaled measurement value goes
lower than this threshold, a fault is generated. It is also used to generate a warning when the scaled
measurement value is within 5% of the error threshold.
Synapticon Documentation
© 2021 Synapticon GmbH | Daimlerstraße 26 | D-71101 Schönaich Documentation v 4.19.0 | Built 2022-02-01
798/1031