1.3.2.1.3.4 Analog IN
Note
Details about measuring Analog signals can be found in our
system integration guideline: Connecting
Pin
#
Default Setting *
Object Mapping
1
–
2
Analog Input 1 -
Connect to Ground **
3
Analog Input 1 +
Single-ended 0-10 V
Analog input 1 (0x2401)
4
Ground
5
Analog Input 2 -
Connect to Ground **
6
Analog Input 2 +
Single-ended 0-10 V
Analog input 2 (0x2402)
7
5 V ***
8
10 V ****
9
Analog Input 3 -
Differential ±5 V
Analog input 3 (0x2403)
10
Analog Input 3 +
Differential ±5 V
Analog input 3 (0x2403)
11
Analog Input 4 -
Differential ±5 V
Analog input 4 (0x2404)
12
Analog Input 4 +
Differential ±5 V
Analog input 4 (0x2404)
* All Analog Inputs can be configured as single-ended 0-5 V, 0-10 V, 0-20 V or differential ±5 V, ±10 V
independently.