![SYNAPTICON SOMANET Circulo 7 Скачать руководство пользователя страница 558](http://html1.mh-extra.com/html/synapticon/somanet-circulo-7/somanet-circulo-7_documentation_1420513558.webp)
V represents the value of voltage at which the ADC is connected to, causing the ADC to count an output
of 65535.
R represents the pull-up resistor.
R is a resistive sensor, e.g. a thermistor or strain gauge.
V is the voltage that is connected to the selected analog input.
The cut-off frequency of the low-pass filter (0x2038:10) for the analog input can also be tweaked to further
fine-tune the unscaled analog input before feeding it to the scaling algorithm.
cc
p
th
in
3.1.4.2.2.3 Thresholds
Upper and lower level thresholds can be configured in subitems 0x2038:11 and 0x2038:12. When these
thresholds are breached, the error ExAnSnsr is triggered in
.
Note
When the value approaches 95% of the defined thresholds, a warning is triggered.
Synapticon Documentation
© 2021 Synapticon GmbH | Daimlerstraße 26 | D-71101 Schönaich Documentation v 4.19.0 | Built 2022-02-01
558/1031