In case you are running several servo drives behind a contactor, please use an uni-directional TVS diode on
each drive because of the inductances of the wiring.
1.5.1.2.1.2.3 Connecting a brake
If your system has an attached brake, please connect the brake cables to the brake connector. These two
threads should be twisted together or at least be paired to have a minimum area between them.
Note
This brake integrates Safe Brake Control functionality (SBC).
Synapticon Documentation
© 2021 Synapticon GmbH | Daimlerstraße 26 | D-71101 Schönaich Documentation v 4.19.0 | Built 2022-02-01