![SYNAPTICON SOMANET Circulo 7 Скачать руководство пользователя страница 285](http://html1.mh-extra.com/html/synapticon/somanet-circulo-7/somanet-circulo-7_documentation_1420513285.webp)
Input voltage, logic 0
0-5 V
Galvanic isolation
2 kV Isolation voltage
Input current
Max. 6 mA (@24 VDC)
Test pulse toleration (OSSD output pulses)
Max. 1 ms
Reverse voltage protected
Yes
Allowed discrepancy between digital inputs
100 ms
De-activation time
TBD
Safe brake output (SBC)
Number of digital outputs
2 (dual-channel safety output for one brake
system)
Max. output voltage
Servo drive main power supply (48 VDC)
Min. output voltage
0 V
Max. current.
1 A
Max. peak current.
4 A
Digital output (STO-SBC diagnostic
output)
Galvanic isolation
2 kV Isolation voltage
Max. current
100 mA
Max. continuous voltage across the output
27 V
Max. peak voltage across the output
35 V
Reverse voltage protected
Yes
Max. delay after STO-SBC activation
50 ms
Attention
Servo drives including STO-SBC module shall be used only in Pollution Degree environments class PD 2
according to IEC 61800-5-1: During normal operation only non-conductive pollution may occur,
temporarily occurring conductivity caused by condensation may only be expected when the servo drive
is out of operation.
Synapticon Documentation
© 2021 Synapticon GmbH | Daimlerstraße 26 | D-71101 Schönaich Documentation v 4.19.0 | Built 2022-02-01
285/1031