7 Teleservice Application Framework
User Manual
177/374
7.3.5.4.3
ydatad_load_datapool_names
Function Description
sint32
ydatad_load_datapool_names (const charn * const opcn_Path)
This command skims through the base folder and creates a data pool structure for each subfolder that contains
a valid data pool.
Information Flow
Input Information
Parameter
Range
Description
opcn_Path
maximum
MAX_DP_BASEFOLDER_LENGHT
pointer to the base folder of the data pools
Output Information
Return Value
Description
C_NO_ERR
Function executed without error
C_UNKNOWN_ERR
NULL pointer
C_RANGE
No data pools available or path size error
Example
// Global module
sint32 s32_Retval;
T_DBUS_Util mt_DBUS_Util;
charn acn_HelpString[MAX_DP_BASEFOLDER_LENGHT];
s32_Retval = ydatad_get_datapool_base_path (&mt_DBUS_Util, acn_HelpString,
sizeof(acn_HelpString));
if (s32_Retval != C_NO_ERR)
{
// Error handling
}
s32_Retval = ydatad_load_datapool_names (acn_HelpString)
if (s32_Retval != C_NO_ERR)
{
// Error handling
}
Содержание TC1
Страница 1: ...TC1 User Manual Version of this document V1 00r0 ...
Страница 25: ...5 Hardware User Manual 25 374 5 2 2 Block Diagram Variant TC1 WIFI ...
Страница 34: ...5 Hardware User Manual 34 374 5 6 Housing Connector Top view and side view Bottom View ...
Страница 125: ...7 Teleservice Application Framework User Manual 125 374 TAF overview ...
Страница 174: ...7 Teleservice Application Framework User Manual 174 374 ADDRESS 6 SIZE 4 TYPE UINT32 UNIT COMMENT EnginePower ...
Страница 190: ...7 Teleservice Application Framework User Manual 190 374 How the logger mechanism works ...
Страница 223: ...7 Teleservice Application Framework User Manual 223 374 Association between logic hysteresis and threshold ...
Страница 293: ...8 Development Tools User Manual 293 374 3 Adapt the Build Options in order to build the binary with debug symbols ...
Страница 302: ...8 Development Tools User Manual 302 374 2 Adapt the Build Options in order to build the binary with debug symbols ...