7 Teleservice Application Framework
User Manual
161/374
Parameter
Range
Description
opcn_List
maximum
MAX_DP_NAME_LENGTH
pointer to the name of the variable list
opcn_Name
maximum
MAX_DP_NAME_LENGTH
pointer to the name of the variable
opcn_Type
maximum
MAX_DP_TYPENAME_LENGTH,
allowed types:
"UINT8"
"SINT8"
"UINT16"
"SINT16"
"UINT32"
"SINT32"
"FLOAT32"
"AOBYTE"
"STRING"
pointer to the type of the variable
opcn_Size
maximum
MAX_DP_SIZE_LENGTH,
allowed type size:
"UINT8" = 1
"SINT8" = 1
"UINT16" = 2
"SINT16" = 2
"UINT32" = 4
"SINT32" = 4
"FLOAT32" = 4
"AOBYTE" =
sizeof
(au8_byte)
"STRING" =
strlen
(acn_string)
pointer to the size in byte of the type
opcn_Unit
maximum
MAX_DP_METANAME_LENGTH
pointer to the user defined unit of the variable
opcn_Comment
maximum
MAX_DP_METANAME_LENGTH
pointer to the variable description
Содержание TC1
Страница 1: ...TC1 User Manual Version of this document V1 00r0 ...
Страница 25: ...5 Hardware User Manual 25 374 5 2 2 Block Diagram Variant TC1 WIFI ...
Страница 34: ...5 Hardware User Manual 34 374 5 6 Housing Connector Top view and side view Bottom View ...
Страница 125: ...7 Teleservice Application Framework User Manual 125 374 TAF overview ...
Страница 174: ...7 Teleservice Application Framework User Manual 174 374 ADDRESS 6 SIZE 4 TYPE UINT32 UNIT COMMENT EnginePower ...
Страница 190: ...7 Teleservice Application Framework User Manual 190 374 How the logger mechanism works ...
Страница 223: ...7 Teleservice Application Framework User Manual 223 374 Association between logic hysteresis and threshold ...
Страница 293: ...8 Development Tools User Manual 293 374 3 Adapt the Build Options in order to build the binary with debug symbols ...
Страница 302: ...8 Development Tools User Manual 302 374 2 Adapt the Build Options in order to build the binary with debug symbols ...