7 Teleservice Application Framework
User Manual
164/374
Return Value
Description
C_NOACT
Error occurred because the data pool or variable list was already initialized,
variable list does not exist, determinate shared memory size failed or allocating of
a shared memory segment failed
C_RANGE
Parameters are out of range
Example
// Global module
T_DBUS_Util mt_DBUS_Util;
sint32 s32_Retval;
s32_Retval = ydatad_init_variable_list (&mt_DBUS_Util, "MyDatapool", "GPSDates");
if (s32_Retval == C_NO_ERR)
{
// Go on
}
7.3.5.2.4
ydatad_delete_variable_list
Function Description
sint32
ydatad_delete_variable_list (const T_DBUS_Util *const
opt_DBusInstance,
const charn *
const opcn_Datapool ,
const charn *const opcn_List)
The function deletes the shared memory segment for the named variable list ocn_List and the according
variable list file in the data pool ocn_Datapool.
Information Flow
Input Information
Parameter
Range
Description
opt_DBusInstance
T_DBUS_Util
holds all D-BUS information
opcn_Datapool
maximum
MAX_DP_NAME_LENGTH
pointer to the name of the data pool
opcn_List
maximum
MAX_DP_NAME_LENGTH
pointer to the name of the variable list
NOTE:
The variable list can only be deleted if it was initialized before.
Содержание TC1
Страница 1: ...TC1 User Manual Version of this document V1 00r0 ...
Страница 25: ...5 Hardware User Manual 25 374 5 2 2 Block Diagram Variant TC1 WIFI ...
Страница 34: ...5 Hardware User Manual 34 374 5 6 Housing Connector Top view and side view Bottom View ...
Страница 125: ...7 Teleservice Application Framework User Manual 125 374 TAF overview ...
Страница 174: ...7 Teleservice Application Framework User Manual 174 374 ADDRESS 6 SIZE 4 TYPE UINT32 UNIT COMMENT EnginePower ...
Страница 190: ...7 Teleservice Application Framework User Manual 190 374 How the logger mechanism works ...
Страница 223: ...7 Teleservice Application Framework User Manual 223 374 Association between logic hysteresis and threshold ...
Страница 293: ...8 Development Tools User Manual 293 374 3 Adapt the Build Options in order to build the binary with debug symbols ...
Страница 302: ...8 Development Tools User Manual 302 374 2 Adapt the Build Options in order to build the binary with debug symbols ...