# The hardware watchdog path ensures that the user space scheduling is running properly.
# Max. path length is 255
# If the path is deactivated or no path is set, an error message will be put on stdout.
watchdog_path /dev/watchdog
# Watchdog interval is set in seconds. Min. 0 / max. 0xFFFFFFFF, recommended min. 30s /
max. is 100s, default interval is 30s
# If no interval is set, then the default interval of 30s will be set.
watchdog_interval 30
Section: Shutdown run time path
# The shutdown run time path includes the run time in seconds after shutdown (ignition
off). When the ignition pins
# goes off, the controller (TC1 can keep on running for a certain amount of time. User
space applications can also
# set the desired time.
# Max. path length 255
# If the path is deactivated or no path is set, an error message will be put on stdout.
runtimefile_path /tmp/sdruntime
Section: Run time interval
# The run time interval is in seconds. Min. 0, Max. recommended 10s, default interval 5s
# If no interval is set, the default interval will be set.
run_interval 5
Section: DPlus inversion
# On some devices it is necessary to invert the dplus pin. Per default, the
# inversion of the pin of off (default value : 0) To activate the inversion,
# set the value to 1
dplus_inv 0
NOTE:
This file will be set by the boot up script at boot time, but it can be overwritten by applications
anytime before the ignition goes off.
Содержание TC1
Страница 1: ...TC1 User Manual Version of this document V1 00r0 ...
Страница 25: ...5 Hardware User Manual 25 374 5 2 2 Block Diagram Variant TC1 WIFI ...
Страница 34: ...5 Hardware User Manual 34 374 5 6 Housing Connector Top view and side view Bottom View ...
Страница 125: ...7 Teleservice Application Framework User Manual 125 374 TAF overview ...
Страница 174: ...7 Teleservice Application Framework User Manual 174 374 ADDRESS 6 SIZE 4 TYPE UINT32 UNIT COMMENT EnginePower ...
Страница 190: ...7 Teleservice Application Framework User Manual 190 374 How the logger mechanism works ...
Страница 223: ...7 Teleservice Application Framework User Manual 223 374 Association between logic hysteresis and threshold ...
Страница 293: ...8 Development Tools User Manual 293 374 3 Adapt the Build Options in order to build the binary with debug symbols ...
Страница 302: ...8 Development Tools User Manual 302 374 2 Adapt the Build Options in order to build the binary with debug symbols ...