7 Teleservice Application Framework
User Manual
160/374
Output Information
Return Value
Description
C_NO_ERR
Function executed without error
C_UNKNOWN_ERR
Error sending the method call or null pointer
C_COM
Error receiving the method call answer
C_NOACT
Error occurs because data pool is already initialized or variable list already exists
C_RANGE
Parameters are out of range
Example
// Global module
T_DBUS_Util mt_DBUS_Util;
sint32 s32_Retval;
s32_Retval = ydatad_create_variable_list (&mt_DBUS_Util, "MyDatapool", "GPSDates",
"Description", "MyApplication");
if (s32_Retval == C_NO_ERR)
{
// Go on
}
7.3.5.2.2
ydatad_add_variable_to_list
Function Description
sint32 ydatad_add_variable_to_list (const T_DBUS_Util const *const
opt_DBusInstance,
const
charn * const opcn_Datapool ,
const charn *const opcn_List, const charn * const opcn_Name,
const charn * const opcn_Type, const charn * const opcn_Size, const charn * const
opcn_Unit, const charn * const opcn_Comment)
The function adds a variable with the name opcn_Name of the type opcn_Type, the size opcn_Size to the
specified list opcn_List within the data pool opcn_Datapool. It's also possible to add a unit opcn_Unit and a
comment opcn_Comment to the variable declaration.
Information Flow
Input Information
Parameter
Range
Description
opt_DBusInstance
T_DBUS_Util
holds all D-BUS information
opcn_Datapool
maximum
MAX_DP_NAME_LENGTH
pointer to the data pool name
NOTE:
It's not possible to add variables to already initialized lists or initialized data pools.
Содержание TC1
Страница 1: ...TC1 User Manual Version of this document V1 00r0 ...
Страница 25: ...5 Hardware User Manual 25 374 5 2 2 Block Diagram Variant TC1 WIFI ...
Страница 34: ...5 Hardware User Manual 34 374 5 6 Housing Connector Top view and side view Bottom View ...
Страница 125: ...7 Teleservice Application Framework User Manual 125 374 TAF overview ...
Страница 174: ...7 Teleservice Application Framework User Manual 174 374 ADDRESS 6 SIZE 4 TYPE UINT32 UNIT COMMENT EnginePower ...
Страница 190: ...7 Teleservice Application Framework User Manual 190 374 How the logger mechanism works ...
Страница 223: ...7 Teleservice Application Framework User Manual 223 374 Association between logic hysteresis and threshold ...
Страница 293: ...8 Development Tools User Manual 293 374 3 Adapt the Build Options in order to build the binary with debug symbols ...
Страница 302: ...8 Development Tools User Manual 302 374 2 Adapt the Build Options in order to build the binary with debug symbols ...