7 Teleservice Application Framework
User Manual
245/374
Parameter:
Input:
Variable
Variable Type
Description
block_len_n
uint16
Size of va 2 bytes for index (for binary
format only)
var_index_n
uint16
Index of variables to be written
value_n
Value of variable. Size (m) specified by var_index
(via KSP file) and block_len_n-2
Output:
Variable
Variable Type
Description
error_code
uint16
0: no error occurred, else command failed
DLTS
– Datalogger transmission size
Syntax of command:
DLTS;<transmission size in bytes>
Syntax of response:
DLTS;<error_code>
Description:
Set the maximum transmission size before a result.xxx.end file is created. The default value is 0. In that case,
the
logger will transmit all logged data before a *.end file is created.
Parameter:
Input:
Variable
Variable Type
Description
transmission size in bytes
uint32
transmission size in bytes
Содержание TC1
Страница 1: ...TC1 User Manual Version of this document V1 00r0 ...
Страница 25: ...5 Hardware User Manual 25 374 5 2 2 Block Diagram Variant TC1 WIFI ...
Страница 34: ...5 Hardware User Manual 34 374 5 6 Housing Connector Top view and side view Bottom View ...
Страница 125: ...7 Teleservice Application Framework User Manual 125 374 TAF overview ...
Страница 174: ...7 Teleservice Application Framework User Manual 174 374 ADDRESS 6 SIZE 4 TYPE UINT32 UNIT COMMENT EnginePower ...
Страница 190: ...7 Teleservice Application Framework User Manual 190 374 How the logger mechanism works ...
Страница 223: ...7 Teleservice Application Framework User Manual 223 374 Association between logic hysteresis and threshold ...
Страница 293: ...8 Development Tools User Manual 293 374 3 Adapt the Build Options in order to build the binary with debug symbols ...
Страница 302: ...8 Development Tools User Manual 302 374 2 Adapt the Build Options in order to build the binary with debug symbols ...