7 Teleservice Application Framework
User Manual
152/374
Return Value
Description
C_BUSY
Error registering a watchdog service from the ysysd (pending call)
C_UNKNOWN_ERR
Error registering a watchdog service from the ysysd (stealing reply)
C_CONFIG
Error registering a watchdog service from the ysysd (Message has no arguments)
C_COM
Error registering a watchdog service from the ysysd (Answer is not a string).
Example
// Global module
T_DBUS_Util mt_DBUS_Util;
sint32 s32_Retval;
s32_Retval = ysysd_register_watch_dog (&mt_DBUS_Util);
if (s32_Retval != C_NO_ERR)
{
// Handle error cases
}
7.3.4.3
ysysd_trigger_watch_dog
Function Description
sint32 ysysd_trigger_watch_dog (const
T_DBUS_Util * const opt_DBusInstance)
Sends a trigger over the D-Bus to the system daemon to prevent it to kill the application. This functions needs
to be called within the registered time interval (set during the ysysd_register_watch_dog function call in the
parameter opt_DBusInstance).
Information Flow
Input Information
Parameter
Range
Description
opt_DBusInstance
T_DBUS_Util
holds all D-Bus information
Structure T_DBUS_Util
typedef struct
{
DBusConnection* pt_dbus_conn;
// D-BUS connection instance
charn acn_myNameString[128];
// Name of the application, Don't use any
special
// characters, white spaces or new lines!
charn acn_myVersion[128];
// Additional value (for HELLO) signal (opt.)
charn acn_myStatus[128];
// Additional value (for HELLO) signal (opt.)
charn acn_myAddInfo[512];
// Additional value (for HELLO) signal (opt.)
sint32 s32_myTriginterval;
// Time interval when the ysysd
// expects to be triggered
charn acn_myCMDOnWatchdog[2048];
// Bash cmd that must be executed
// by the ysysd in case no
// trigger signal occurred in time.
} T_DBUS_Util;
Содержание TC1
Страница 1: ...TC1 User Manual Version of this document V1 00r0 ...
Страница 25: ...5 Hardware User Manual 25 374 5 2 2 Block Diagram Variant TC1 WIFI ...
Страница 34: ...5 Hardware User Manual 34 374 5 6 Housing Connector Top view and side view Bottom View ...
Страница 125: ...7 Teleservice Application Framework User Manual 125 374 TAF overview ...
Страница 174: ...7 Teleservice Application Framework User Manual 174 374 ADDRESS 6 SIZE 4 TYPE UINT32 UNIT COMMENT EnginePower ...
Страница 190: ...7 Teleservice Application Framework User Manual 190 374 How the logger mechanism works ...
Страница 223: ...7 Teleservice Application Framework User Manual 223 374 Association between logic hysteresis and threshold ...
Страница 293: ...8 Development Tools User Manual 293 374 3 Adapt the Build Options in order to build the binary with debug symbols ...
Страница 302: ...8 Development Tools User Manual 302 374 2 Adapt the Build Options in order to build the binary with debug symbols ...