7 Teleservice Application Framework
User Manual
225/374
7.3.6.4
Handle Logger File
Header file: "DL_LogFile_handler.h"
This header provides utility functions to use the logger daemon to handle logger files.
7.3.6.4.1
ylogd_request_data_logger_file
Function Description
sint32
ylogd_request_data_logger_file (const T_DBUS_Util *const
opt_DBusInstance,
const
charn * const opcn_DataLoggerName, charn * const opcn_DataLoggerPath, const uint16
ou16_BufferSize)
The function requests the datalogger file opcn_DataLoggerName. If the logger file exists, the path to a copy
(tmp file) will be responded via the variable opcn_DataLoggerPath. The maximal length of the path to the
datalogger copy is defined via ou16_BufferSize.
Information Flow
Input Information
Parameter
Range
Description
opt_DBusInstance
T_DBUS_Util
holds all D-Bus information
opcn_DataLoggerName maximum
MAX_DL_NAME_LENGTH
pointer to the name of the datalogger
ou16_BufferSize
minimum
MAX_DL_BASEFOLDER_LENGTH
maximum buffer size of datalogger path
Structure T_DBUS_Util
typedef struct
{
DBusConnection* pt_dbus_conn;
// D-BUS connection instance
charn acn_myNameString[128];
// Name of the application, Don't use any
special
// characters, white spaces or new lines!
charn acn_myVersion[128];
// Additional value (for HELLO) signal (opt.)
charn acn_myStatus[128];
// Additional value (for HELLO) signal (opt.)
charn acn_myAddInfo[512];
// Additional value (for HELLO) signal (opt.)
sint32 s32_myTriginterval;
// Time interval when the ysysd
// expects to be triggered
charn acn_myCMDOnWatchdog[2048];
// Bash cmd that must be executed
// by the ysysd in case no
// trigger signal occurred in time.
} T_DBUS_Util;
Содержание TC1
Страница 1: ...TC1 User Manual Version of this document V1 00r0 ...
Страница 25: ...5 Hardware User Manual 25 374 5 2 2 Block Diagram Variant TC1 WIFI ...
Страница 34: ...5 Hardware User Manual 34 374 5 6 Housing Connector Top view and side view Bottom View ...
Страница 125: ...7 Teleservice Application Framework User Manual 125 374 TAF overview ...
Страница 174: ...7 Teleservice Application Framework User Manual 174 374 ADDRESS 6 SIZE 4 TYPE UINT32 UNIT COMMENT EnginePower ...
Страница 190: ...7 Teleservice Application Framework User Manual 190 374 How the logger mechanism works ...
Страница 223: ...7 Teleservice Application Framework User Manual 223 374 Association between logic hysteresis and threshold ...
Страница 293: ...8 Development Tools User Manual 293 374 3 Adapt the Build Options in order to build the binary with debug symbols ...
Страница 302: ...8 Development Tools User Manual 302 374 2 Adapt the Build Options in order to build the binary with debug symbols ...