7 Teleservice Application Framework
User Manual
107/374
be started!
com_server_url teleservice.specific-url.de
Section: Communication protocol download path
# Path for Nextjob.job download on the ComServer
# Use the string <client_id> as a placeholder for the real client ID. The daemon will
replace the string with the real ID.
# Max. path length 512
# If no path is set, an error message will be put on stdout. The specified connection will
not be started!
com_server_path_get ec2c/<client_id>/ToDevice/
Section: Communication protocol upload path
# Path for Nextjob.job upload on the ComServer
# Use the string <client_id> as a placeholder for the real client ID. The daemon will
replace the string with the real ID.
# Max. path length 512
# If no path is set, an error message will be put on stdout. The specified connection will
not be started!
com_server_path_put ec2c/<client_id>
Section: Communication port number
# Port number
# Min. port number is 0, max port number is 0xFFFF, default port number is 80
# If no port number is set, default port will be set (80).
port_no 8080
Section: Basic http authentification
# User name and corresponding password for the HTTP basic authentication is necessary to
access the server
# The maximum length for the user name and also for the password is 30 characters.
http_user test
http_passwd testtest
Section: Protocol file name from server
# Command file name from Com-Server
# Min. command length is 1, max. command length is 512
# If no command is set, an error message will be put on stdout. The specific connection
will not be started!
srv_cmd_file NextJob.job
Section: User file name from device
# Command file name from device
# Min. command length is 1, max. command length is 512
# If no command is set, an error message will be put on stdout. The specific connection
WARNING:
Use only characters [0..9] for the port. Using other characters forces a system fault.
Содержание TC1
Страница 1: ...TC1 User Manual Version of this document V1 00r0 ...
Страница 25: ...5 Hardware User Manual 25 374 5 2 2 Block Diagram Variant TC1 WIFI ...
Страница 34: ...5 Hardware User Manual 34 374 5 6 Housing Connector Top view and side view Bottom View ...
Страница 125: ...7 Teleservice Application Framework User Manual 125 374 TAF overview ...
Страница 174: ...7 Teleservice Application Framework User Manual 174 374 ADDRESS 6 SIZE 4 TYPE UINT32 UNIT COMMENT EnginePower ...
Страница 190: ...7 Teleservice Application Framework User Manual 190 374 How the logger mechanism works ...
Страница 223: ...7 Teleservice Application Framework User Manual 223 374 Association between logic hysteresis and threshold ...
Страница 293: ...8 Development Tools User Manual 293 374 3 Adapt the Build Options in order to build the binary with debug symbols ...
Страница 302: ...8 Development Tools User Manual 302 374 2 Adapt the Build Options in order to build the binary with debug symbols ...