7 Teleservice Application Framework
User Manual
105/374
7.2.7
Server daemon
Daemon location
Configuration file
/usr/local/bin/yserverd
/etc/init.d/_yserverd.config
How to activate the configuration file of the server daemon
Activate the configuration file of the server daemon, so the server daemon is started during the boot up
sequence automatically.
1. Rename the configuration file of the ydatad the following way:
# mv /etc/init.d/_yserverd.config /etc/init.d/yserverd.config
2. Reboot the system
# reboot
yserverd
The server daemon provides functions to manage the communication with an external server automatically.The
server daemon communicates with an external server (like ComServer).
The yserverd uses one of the interfaces selected in the ynetworkd. In a periodic interval, the server daemon
requests a specified file from the server.This file can be configured in the yserverd specific configuration file.
Via HTTP the file is requested and afterwards interpreted. All known commands are send to the corresponding
daemons. After the command was completed, it's also possible to send a reply to the external server.
The server daemon is configured with two configuration files:
The general configuration file (/etc/init.d/yserverd.config) is used for all started daemon instances. It
includes the default paths like watchdog interval, reboot command and path to specific configuration files.
The specific configuration file (/opt/yserverd/configuration/<CONFIG_NAME>.config) that includes
communication specific settings, like communication URL, port, protocol.
Properties for the specific configuration file:
Содержание TC1
Страница 1: ...TC1 User Manual Version of this document V1 00r0 ...
Страница 25: ...5 Hardware User Manual 25 374 5 2 2 Block Diagram Variant TC1 WIFI ...
Страница 34: ...5 Hardware User Manual 34 374 5 6 Housing Connector Top view and side view Bottom View ...
Страница 125: ...7 Teleservice Application Framework User Manual 125 374 TAF overview ...
Страница 174: ...7 Teleservice Application Framework User Manual 174 374 ADDRESS 6 SIZE 4 TYPE UINT32 UNIT COMMENT EnginePower ...
Страница 190: ...7 Teleservice Application Framework User Manual 190 374 How the logger mechanism works ...
Страница 223: ...7 Teleservice Application Framework User Manual 223 374 Association between logic hysteresis and threshold ...
Страница 293: ...8 Development Tools User Manual 293 374 3 Adapt the Build Options in order to build the binary with debug symbols ...
Страница 302: ...8 Development Tools User Manual 302 374 2 Adapt the Build Options in order to build the binary with debug symbols ...