10 Application Notes
User Manual
320/374
10.1.7
CAN
CAN-Termination
According to the CAN specification, every end of a CAN bus trunk-line must be terminated with a 120 Ohm
Resistor.
Example of a terminated CAN bus:
CAN-Bus length (Trunk-line length)
The CAN bus length (Trunk-line length) is limited and depends on the Baud-rate, the CAN bus is operated with.
The following table shall give an overview of maximum CAN bus length according to the used Baud rate.
Baud-Rate [kbit/s]
CAN-bus length
1000 (1MBit/s)
< 20m
500
< 100
250
< 250
125
< 500
50
< 1000
20
< 2500
10
< 5000
Drop-line length
Drop-lines are allowed, but should be avoided, as they typically create signal echo. Drop-lines must not be
terminated with 120 Ohm resistors! The following table shows the maximum lengths of drop-lines to be used:
Baud-Rate
[kBit/s]
Drop-line length
[m]
Total length of all drop-lines
[m]
1000 (1Mb/s)
< 1
< 5
500
< 5
< 25
250
< 10
< 50
Содержание TC1
Страница 1: ...TC1 User Manual Version of this document V1 00r0 ...
Страница 25: ...5 Hardware User Manual 25 374 5 2 2 Block Diagram Variant TC1 WIFI ...
Страница 34: ...5 Hardware User Manual 34 374 5 6 Housing Connector Top view and side view Bottom View ...
Страница 125: ...7 Teleservice Application Framework User Manual 125 374 TAF overview ...
Страница 174: ...7 Teleservice Application Framework User Manual 174 374 ADDRESS 6 SIZE 4 TYPE UINT32 UNIT COMMENT EnginePower ...
Страница 190: ...7 Teleservice Application Framework User Manual 190 374 How the logger mechanism works ...
Страница 223: ...7 Teleservice Application Framework User Manual 223 374 Association between logic hysteresis and threshold ...
Страница 293: ...8 Development Tools User Manual 293 374 3 Adapt the Build Options in order to build the binary with debug symbols ...
Страница 302: ...8 Development Tools User Manual 302 374 2 Adapt the Build Options in order to build the binary with debug symbols ...