7 Teleservice Application Framework
User Manual
156/374
7.3.4.6
ysysd_request_stay_alive
Function Description
sint32 ysysd_request_stay_alive (const T_DBUS_Util * const opt_DBusInstance, const uint32
ou32_DurationSec
)
With this function the system daemon receives over the D-Bus the command not to shutdown the system, for at
least the demanded amount of time in seconds.
If the state of the ignition pin switches to low and the configured time has elapsed, the system shuts down.
If your application is in a crucial task that must not be interrupted (e.g. saving data to flash, transferring data to
the server), then use this function so that the TC1 stays alive for the time specified with ou32_DurationSec,
until this crucial task is finished.
Information Flow
Input Information
Parameter
Range
Description
opt_DBusInstance
T_DBUS_Util
holds all D-Bus information
ou32_DurationSec
minimum 1
time in seconds, the system should stay alive
from now on
Structure T_DBUS_Util
typedef struct
{
DBusConnection* pt_dbus_conn;
// D-BUS connection instance
charn acn_myNameString[128];
// Name of the application, Don't use any
special
// characters, white spaces or new lines!
charn acn_myVersion[128];
// Additional value (for HELLO) signal (opt.)
charn acn_myStatus[128];
// Additional value (for HELLO) signal (opt.)
charn acn_myAddInfo[512];
// Additional value (for HELLO) signal (opt.)
sint32 s32_myTriginterval;
// Time interval when the ysysd
// expects to be triggered
charn acn_myCMDOnWatchdog[2048];
// Bash cmd that must be executed
// by the ysysd in case no
// trigger signal occurred in time.
} T_DBUS_Util;
Output Information
Return Value
Description
C_NO_ERR
system daemon accepted the command
C_UNKNOWN_ERR
Could not sent the stay alive request to the system daemon (right ysysd version,
daemon running?)
C_RANGE
requested duration is 0 or opt_DBusInstance is a NULL pointer
Содержание TC1
Страница 1: ...TC1 User Manual Version of this document V1 00r0 ...
Страница 25: ...5 Hardware User Manual 25 374 5 2 2 Block Diagram Variant TC1 WIFI ...
Страница 34: ...5 Hardware User Manual 34 374 5 6 Housing Connector Top view and side view Bottom View ...
Страница 125: ...7 Teleservice Application Framework User Manual 125 374 TAF overview ...
Страница 174: ...7 Teleservice Application Framework User Manual 174 374 ADDRESS 6 SIZE 4 TYPE UINT32 UNIT COMMENT EnginePower ...
Страница 190: ...7 Teleservice Application Framework User Manual 190 374 How the logger mechanism works ...
Страница 223: ...7 Teleservice Application Framework User Manual 223 374 Association between logic hysteresis and threshold ...
Страница 293: ...8 Development Tools User Manual 293 374 3 Adapt the Build Options in order to build the binary with debug symbols ...
Страница 302: ...8 Development Tools User Manual 302 374 2 Adapt the Build Options in order to build the binary with debug symbols ...