7 Teleservice Application Framework
User Manual
198/374
Structure T_DBUS_Util
typedef struct
{
DBusConnection* pt_dbus_conn;
// D-BUS connection instance
charn acn_myNameString[128];
// Name of the application, Don't use any
special
// characters, white spaces or new lines!
charn acn_myVersion[128];
// Additional value (for HELLO) signal (opt.)
charn acn_myStatus[128];
// Additional value (for HELLO) signal (opt.)
charn acn_myAddInfo[512];
// Additional value (for HELLO) signal (opt.)
sint32 s32_myTriginterval;
// Time interval when the ysysd
// expects to be triggered
charn acn_myCMDOnWatchdog[2048];
// Bash cmd that must be executed
// by the ysysd in case no
// trigger signal occurred in time.
} T_DBUS_Util;
Output Information
Return Value
Description
C_NO_ERR
Function executed without error
event condition was successfully set
C_COM
D-Bus communication error
C_UNKNOWN_ERR
NULL pointer error or wrong parameters
C_NOACT
Error occurs because:
log job name invalid
log job does not exist
log job active, variable does not exist in data pool
cannot update log job
C_RANGE
Parameters are out of range
7.3.6.2.4
ylogd_set_log_mechanism
Function Description
sint32
ylogd_set_log_mechanism (const T_DBUS_Util *const
opt_DBusInstance,
const charn *
const opcn_LogJobName, const uint8 ou8_LogMechanism)
The function sets the log mechanism for the selected logger specified in name opcn_LogJobName.
NOTE:
For an illustration of the logging sequence see How the logger mechanism works (see "
on page 189).
Содержание TC1
Страница 1: ...TC1 User Manual Version of this document V1 00r0 ...
Страница 25: ...5 Hardware User Manual 25 374 5 2 2 Block Diagram Variant TC1 WIFI ...
Страница 34: ...5 Hardware User Manual 34 374 5 6 Housing Connector Top view and side view Bottom View ...
Страница 125: ...7 Teleservice Application Framework User Manual 125 374 TAF overview ...
Страница 174: ...7 Teleservice Application Framework User Manual 174 374 ADDRESS 6 SIZE 4 TYPE UINT32 UNIT COMMENT EnginePower ...
Страница 190: ...7 Teleservice Application Framework User Manual 190 374 How the logger mechanism works ...
Страница 223: ...7 Teleservice Application Framework User Manual 223 374 Association between logic hysteresis and threshold ...
Страница 293: ...8 Development Tools User Manual 293 374 3 Adapt the Build Options in order to build the binary with debug symbols ...
Страница 302: ...8 Development Tools User Manual 302 374 2 Adapt the Build Options in order to build the binary with debug symbols ...