7 Teleservice Application Framework
User Manual
110/374
The following states can be displayed:
State of the module
LED color
Description
Power ON
yellow
This state is active when the TC3G has booted
and none of the other states are active.
GPS
blue
This state is active when ygpsd is activated and a
valid NMEA string is received and the internet-
state is not active.
Internet
pink
This state is active when ynetworkd is activated
and a valid connection to the internet exists and
the GPS-state is not active. This is also verified
by a ‘ping’ signal or a file download.
GPS + Internet
green
This state is active when the ‘GPS’ state and the
‘Internet’ state are both active.
CAN traffic
flashing LED, without changing
its color
This state is active when there is traffic on CAN0
or CAN1.
Error
blink code initialized by a 'red'
LED signal
This state is active when a ‘Goodbye’ signal from
a daemon is received or when a valid entry in the
/tmp/LED_Error file exists.
User
blink code initialized by a pause
of the LED signal
This state is active when a valid entry in the
/tmp/LED_User file exists.
The signal daemon checks if the variant supports:
GPS
GSM
WLAN
BT
If the variant does not support GPS, then the 'GPS + Internet' state will never be reached. Therefore, the color
of the 'Internet' state is set to 'green'.
NOTE:
The 'CAN traffic' state will not be signalized when the 'Error' state is active.
The 'User' state is signalized parallel to all other states.
NOTE:
If the LED signal is 'green', all possible states, depending on the variant, are reached.
Содержание TC1
Страница 1: ...TC1 User Manual Version of this document V1 00r0 ...
Страница 25: ...5 Hardware User Manual 25 374 5 2 2 Block Diagram Variant TC1 WIFI ...
Страница 34: ...5 Hardware User Manual 34 374 5 6 Housing Connector Top view and side view Bottom View ...
Страница 125: ...7 Teleservice Application Framework User Manual 125 374 TAF overview ...
Страница 174: ...7 Teleservice Application Framework User Manual 174 374 ADDRESS 6 SIZE 4 TYPE UINT32 UNIT COMMENT EnginePower ...
Страница 190: ...7 Teleservice Application Framework User Manual 190 374 How the logger mechanism works ...
Страница 223: ...7 Teleservice Application Framework User Manual 223 374 Association between logic hysteresis and threshold ...
Страница 293: ...8 Development Tools User Manual 293 374 3 Adapt the Build Options in order to build the binary with debug symbols ...
Страница 302: ...8 Development Tools User Manual 302 374 2 Adapt the Build Options in order to build the binary with debug symbols ...