7 Teleservice Application Framework
User Manual
192/374
Structure T_DBUS_Util
typedef struct
{
DBusConnection* pt_dbus_conn;
// D-BUS connection instance
charn acn_myNameString[128];
// Name of the application, Don't use any
special
// characters, white spaces or new lines!
charn acn_myVersion[128];
// Additional value (for HELLO) signal (opt.)
charn acn_myStatus[128];
// Additional value (for HELLO) signal (opt.)
charn acn_myAddInfo[512];
// Additional value (for HELLO) signal (opt.)
sint32 s32_myTriginterval;
// Time interval when the ysysd
// expects to be triggered
charn acn_myCMDOnWatchdog[2048];
// Bash cmd that must be executed
// by the ysysd in case no
// trigger signal occurred in time.
} T_DBUS_Util;
Output Information
Return Value
Description
C_NO_ERR
Function executed without error, job successfully created
C_UNKNOWN_ERR
Error occurs during sending the method call or NULL pointer
C_COM
Error occurs during receiving the method call answer
C_NOACT
Error occurs because logger job name or log file format invalid, basic sample
interval too short or logger job configuration already exists
C_RANGE
Parameters are out of range
Logfile format description
ASCII_STD
Log File header:
----------------
LOGFILE_HEADER
LogFile;Test_Logger
LogFileFormat;1
Comment;Test log job for Test
MaxSize;10485760
Date+Time;22.11.11_13:30:53
FileInfo:
Timestamp:1
DP :00;Test
Lst:00;Engine
Var:00;EngineSpeed;Type:SINT32;Size:4;Unit:rpm
Var:01;InjectionQuantity;Type:SINT32;Size:4;Unit:mm3/H
Var:02;EnginePowerReserve;Type:SINT32;Size:4;UNIT:%
DATASTART
Time stamp
;
Index
;
VAR Name
;
Value ;
Index
;
VAR Name
;
Value
;
...
;
Содержание TC1
Страница 1: ...TC1 User Manual Version of this document V1 00r0 ...
Страница 25: ...5 Hardware User Manual 25 374 5 2 2 Block Diagram Variant TC1 WIFI ...
Страница 34: ...5 Hardware User Manual 34 374 5 6 Housing Connector Top view and side view Bottom View ...
Страница 125: ...7 Teleservice Application Framework User Manual 125 374 TAF overview ...
Страница 174: ...7 Teleservice Application Framework User Manual 174 374 ADDRESS 6 SIZE 4 TYPE UINT32 UNIT COMMENT EnginePower ...
Страница 190: ...7 Teleservice Application Framework User Manual 190 374 How the logger mechanism works ...
Страница 223: ...7 Teleservice Application Framework User Manual 223 374 Association between logic hysteresis and threshold ...
Страница 293: ...8 Development Tools User Manual 293 374 3 Adapt the Build Options in order to build the binary with debug symbols ...
Страница 302: ...8 Development Tools User Manual 302 374 2 Adapt the Build Options in order to build the binary with debug symbols ...