13 Qualification Tests
User Manual
367/374
Standard
Test description
Parameter
ISO 10605
ESD - Component immunity test
method
(powered-up test)
Contact discharge ± 2 kV / ± 4 kV / ± 8 kV
Air discharge ± 4 kV / ± 8 kV / ± 15 kV
2000 Ω / 330 pF, 2000 Ω / 150 pF
ISO 10605
ESD - Packaging and handling
(unpowered test)
Contact discharge ± 2 kV / ± 4 kV
Air discharge ± 4 kV / ± 8 kV / ± 25 kV
13.4
Electromagnetic Compatibility CE
Standard
Test description
Parameter
DIN EN 61000-6-3
Emission standard for residential,
commercial and light-industrial
environments
150 kHz to 30 MHz conducted,
30 MHz to 1 GHz antenna
DIN EN 61000-6-2
Immunity for industrial environments -
Electrostatic discharge immunity test
DIN EN 61000-4-2
330 Ω / 150 pF
contact discharge ± 4 kV
air discharge ± 8 kV
DIN EN 61000-6-2
Immunity for industrial environments -
Radiated, radio-frequency,
electromagnetic field immunity test
DIN EN 61000-4-3
80 MHz to 1.0 GHz, 10 V/m
1.4 GHz to 2.0 GHz, 3 V/m
2.0 GHz to 2.7 GHz, 1 V/m
3 m, horizontal and vertical
DIN EN 61000-6-2
Immunity for industrial environments -
Immunity to conducted disturbances,
induced by radio-frequency fields
DIN EN 61000-4-6
150 kHz to 80 MHz, 10V, 80 % AM, sinus
at 1 kHz
13.5
EMC Radio and Telecommunications Terminal Equipment
Standard
Test decription
Parameter
1999/5/EC
(R&TTE) Radio equipment and
telecommunications terminal equipment
ETSI EN 301489 - 1
ElectroMagnetic Compatibility (EMC)
standard for radio equipment and
services;
Part 1: Common technical requirements
GPS
ETSI EN 301489 - 7
ElectroMagnetic Compatibility (EMC)
standard for radio equipment and
services;
Part 7: Specific conditions for mobile and
GSM & DCS
Содержание TC1
Страница 1: ...TC1 User Manual Version of this document V1 00r0 ...
Страница 25: ...5 Hardware User Manual 25 374 5 2 2 Block Diagram Variant TC1 WIFI ...
Страница 34: ...5 Hardware User Manual 34 374 5 6 Housing Connector Top view and side view Bottom View ...
Страница 125: ...7 Teleservice Application Framework User Manual 125 374 TAF overview ...
Страница 174: ...7 Teleservice Application Framework User Manual 174 374 ADDRESS 6 SIZE 4 TYPE UINT32 UNIT COMMENT EnginePower ...
Страница 190: ...7 Teleservice Application Framework User Manual 190 374 How the logger mechanism works ...
Страница 223: ...7 Teleservice Application Framework User Manual 223 374 Association between logic hysteresis and threshold ...
Страница 293: ...8 Development Tools User Manual 293 374 3 Adapt the Build Options in order to build the binary with debug symbols ...
Страница 302: ...8 Development Tools User Manual 302 374 2 Adapt the Build Options in order to build the binary with debug symbols ...