PCM-D10
9
Sony CONFIDENTIAL
For Authorized Servicer
7. Press the [
v
DPC]/[ A-B
V
] buttons to select the destination.
Note 4:
Select the “UC” for US model. (It is not “U”)
Note 5:
Select the “UC” for Canadian model. (It is not “CA”)
J Not
used
UC US or Canadian model
J4 Not
used
CA Not
used
LA Not
used
CN Chinese
model
KR3 Not used
E E
model
CE7 Not used
U Not
used
[Current Dest]
E
Select : Up/Down
Save : Play
E
[
v
DPC]
button
[ A-B
V
]
button
8. After selecting the destination, press the [
N
] button to decision
and con
fi
rm that the set destination is displayed under “[Current
Dest]” on the screen.
[Current Dest]
XX
Select : Up/Down
Save : Play
XX
[
N
] button Check the “XX”
UC : US, Canadian models
E : E model
CN : Chinese model
9. Press the [ BACK/ HOME] button to display the test mode
menu.
BT
NFC
Audio Loop
Sine Wave
INT Mic Check
Setting Dest
Debug Mode
Chg Info
To Normal Mode
[Current Dest]
XX
Select : Up/Down
Save : Play
XX
>%$&.+20(@EXWWRQ
10. Press the [
v
DPC]/[ A-B
V
] buttons to select the “Factory
Shipment” and press the [
N
] button to execute.
Note 6:
When “Factory Shipment” is executed, “BD address”, “iSerial” and
“LCD contrast” are not initialized. Files, menu settings and clock
display of the built-in memory is all initialized.
Sleep
OFF DeepSleep
Power Down
Key Count
HotPlug Count
Log
Erase IPL2
Initialize Menu
Factory Shipment
EXEC : Play
[
N
] button
[
v
DPC]
button
[ A-B
V
]
button
11. After “Factory Shipment” is completed, the state of the test
mode is released and the unit reboot automatically (it starts up in
the normal mode).
After the reboot, when the initial settings screen is displayed,
then perform the initial setting such as date etc.
Sleep
OFF DeepSleep
Power Down
Key Count
HotPlug Count
Log
Erase IPL2
Initialize Menu
Factory Shipment
N
Configure
Initial Settings
: Enter
reboot
Normal mode state
(Initial settings screen)
Test mode state
12. The
fi
le of built-in memory that was backup beforehand, return
to the same folder of this unit.
13. Turn off the power of this unit, remove the battery, and complete
the destination setting work.
Ver. 1.1
SYS SET