PCM-D10
27
Sony CONFIDENTIAL
For Authorized Servicer
2-5. CHECKING OPERATION OF THE KNOB (REC VOL)
0
0
1
1
0 0
1 1
3 3
4 4
5 5
3 3
4 4
5 5
0 0
1 1
1010
9 9
1010
9 9
10
10
9
9
8
2
3
4
5
3
4
6
5
3
4
5
3
4
6
5
knob REC VOL assy
L knob (REC VOL)
&KHFNLQJRSHUDWLRQZKHQSXOOLQJRXWWKHNQRE5(&92/DVV\
1
Set to a scale mark other
than “0” and “10”.
2
Pull out the knob REC
VOL assy in the direction
of the arrow.
3
Rotate the knob REC
VOL assy 10 to 30
degrees.
4
Check that the L knob (REC
VOL) does not move while the
knob REC VOL assy rotates.
–
)URQWYLHZ
–
L knob (REC VOL)
&KHFNLQJRSHUDWLRQZKHQV\QFLQJWKH/NQRE5(&92/DQGNQRE5(&92/DVV\
1
Set the scale marks of the L knob (REC VOL)
and knob REC VOL assy to “0” position.
After that, rotate only the knob REC VOL assy
to scale mark “10” position.
Note:
When rotate only the knob REC VOL assy
to scale mark “10” position, make sure you
do not touch the L knob (REC VOL).
knob REC VOL assy
–
)URQWYLHZ
–
2.
NG
2
Check that the L knob (REC VOL)
and knob REC VOL assy line up at
scale mark “10” position.
2.
NG
4
Check that the L knob (REC VOL)
and knob REC VOL assy line up at
scale mark “0” position.
L knob (REC VOL)
knob REC VOL assy
3
Set the scale marks of the L knob (REC VOL)
and knob REC VOL assy to “10” position.
After that, rotate only the knob REC VOL assy
to scale mark “0” position.
Note:
When rotate only the knob REC VOL assy
to scale mark “0” position, make sure you
do not touch the L knob (REC VOL).
Fixed
(does not move)
SYS SET
2019/03/08 01:38:10 (GMT+09:00)