5-54
5-54 E
5. Switch Check (3)
Page 2
Address 54 to 59
Using method:
1) Select page: 2, addresses: 54 to 59.
2) By discriminating the dispaly data, the pressed key can be
discriminated.
7.
Self Diagnosis Code
6.
LED Check
Using method:
1) Select page: 2, address: 06, and set data: 02.
2) Check that all LED except for the ACCESS LED are lit.
3) Select page: 2, address: 06, and set data: 00.
Page 2
Address 06
Data 02
Note :
The error code is cleared if the battery is removed, except defective flash, unit.
*1: When the flash charging failed, Page: D, Address: 67, Data: 04 are written.
After repair, be sure to write Page: D, Address: 67, Data: 00.
[Power supplying Method]
Use the AC power adaptor (AC-L10A) when supplying the power to this set.
Address
Data
00 to 12
13 to 3A
3B to 62
63 to 87
88 to B3
B4 to D5
D6 to FF
54
MACRO
FOCUS
(KEY AD0)
(CF-83 board)
(CF-83 board)
(IC404
uk
)
(S401)
(S402)
55
CONTROL DOWN CONTROL UP
DISPLAY
VOLUME–
LCD ON/OFF
(KEY AD1)
(PK-55 board)
(PK-55 board)
(PK-55 board) (PK-55 board)
(PK-55 board)
(PK-55 board)
(IC404
ul
)
(S701)
(S701)
(S702)
(S704)
(S706)
(S708)
56
CONTROL RIGHT CONTROL LEFT
CONTROL SET
FLASH
(KEY AD2)
(PK-55 board)
(PK-55 board)
(PK-55 board) (PK-55 board)
(IC404
i;
)
(S701)
(S701)
(S701)
(S705)
57
STEADY SHOT
(KEY AD3)
(CF-83 board)
(IC404
ia
)
(S403)
58
PROGRAM AE+ PROGRAM AE–
PROGRAM AE WHITE BALANCE
ONE-PUSH
SPOT METER
(KEY AD4)
(AE-25 board)
(AE-25 board)
(AE-25 board) (AE-25 board) WHITE BALANCE (AE-25 board)
(IC404
is
)
(S356)
(S355)
(S354)
(S353)
(AE-25 board)
(S351)
(S352)
59
OPEN
(KEY AD5)
(FLASH)
(IC404
id
)
(FLASH UNIT)
Display Code
C:32:01
C:13:01
E:91:01
E:61:00
E61:10
Countermeasure
Change the disk and turn off the main
power then back on.
Replace the floppy disk or “Memory
Stick”.
Format the floppy disk or “Memory Stick”
with the MVC-FD97.
Checking of flash unit or replacement of
flash unit
Checking of lens drive circuit
Cause
Defective floppy disk.
• The type of floppy disk that cannot be
used by this machine, is inserted.
(Such as 2DD)
• Data is damaged.
• Unformatted disk or “Memory Stick”
is inserted.
Abnormality when flash is being
charged.
When failed in the focus initialization.
Caution Display During Error
DRIVE ERROR
DISK ERROR
MEMORY STICK ERROR
Flash LED
Flash display
Flashing at 3.2 Hz
—
*1
Содержание FD Mavica MVC-FD97
Страница 97: ...5 29 R Y B Y 4 mm 4 mm Fig 5 1 19 A Fig 5 1 19 B R Y B Y 1 mm 1 mm 6 mm 6 mm ...
Страница 103: ...5 35 H t1 µsec Falling edge of waveform when data is 08 Falling edge of waveform when data is 09 Fig 5 1 21 ...
Страница 143: ... 170 MVC FD97 9 929 887 32 2001F0500 1 2001 6 Published by PV Customer Center Sony EMCS Co Kohda TEC ...