5-28
Order Page Address Data
Procedure
INDOOR data check (with ND filter)
21
F
27
Note down the data.
22
F
27
80
Press PAUSE button.
23
6
1C
03
24
Wait for 1 second.
25
0
03
04
26
1
Check that the displayed data
(Note 2) satisfied the R ratio
specified value.
27
0
03
05
28
1
Check that the displayed data
(Note 2) satisfied the B ratio
specified value.
29
F
27
Set the data noted down at
step 21, and press PAUSE
button.
INDOOR luminance point check
30
6
1C
00
31
0
03
00
32
Check that the center of the
white luminance point within
the circle shown
Fig. 5-1-19 (A).
OUTDOOR luminance check
33
Place the C14 filter on the
lens.
34
E
4B
Note down the data.
35
E
4B
20
Press PAUSE button.
36
6
01
3F
Press PAUSE button.
37
Check that the center of the
white luminance point settles
in the circle shown
Fig. 5-1-19 (B).
Processing after Completing Adjustment:
Order Page Address Data
Procedure
1
6
01
00
Press PAUSE button.
2
6
2C
00
3
6
6C
00
4
E
4B
Set the data noted down at
step 34, and press PAUSE
button.
5
E
52
Set the data noted down at
step 14, and press PAUSE
button.
6
5
F1
FF
7
D
63
00
Press PAUSE button.
8
Release the data setting
performed at step 5.
(Refer to page 5-14)
9
0
01
00
15. Auto White Balance Check
Mode
CAMERA
Subject
Clear chart
(Color reproduction adjustment
frame)
Measurement Point
Displayed data of Video terminal
of Page: 1
A/V OUT jack
(Note 2)
(75
Ω
terminated)
Measuring Instrument
Adjustment remote Vectorscope
commander
Specified Value
R ratio:
Fig. 5-1-19
3E00 to 4200
(A) and (B)
B ratio:
3E00 to 4200
Note 1:
Refer to “Picture Frame Setting” for XH, XL, YH and
YL.
Note 2
: The right 4 digits of the page: 1 displayed data of the
adjusting remote commander.
1:XX:XX
Displayed data
Checking method:
Order Page Address Data
Procedure
1
Check that the lens is not
covered with either filter.
2
0
01
01
3
5
F1
FF
4
D
63
40
Press PAUSE button.
5
Perform “Data setting during
camera system adjustment”.
(Refer to page 5-14)
6
6
90
XL
(Note 1)
7
6
91
XH
(Note 1)
8
6
92
YL
(Note 1)
9
6
93
YH
(Note 1)
10
6
6C
01
11
6
01
79
Press PAUSE button.
12
Wait for 1 second.
13
6
2C
01
INDOOR data check (without ND filter)
14
E
52
Note down the data.
15
E
52
0E
Press PAUSE button.
16
6
01
0F
Press PAUSE button.
17
0
03
04
18
1
Check that the displayed data
(Note 2)satisfied the R ratio
specified value.
19
0
03
05
20
1
Check that the displayed data
(Note 2) satisfied the B ratio
specified value.
Ver 1.1 2001. 06
Содержание FD Mavica MVC-FD97
Страница 97: ...5 29 R Y B Y 4 mm 4 mm Fig 5 1 19 A Fig 5 1 19 B R Y B Y 1 mm 1 mm 6 mm 6 mm ...
Страница 103: ...5 35 H t1 µsec Falling edge of waveform when data is 08 Falling edge of waveform when data is 09 Fig 5 1 21 ...
Страница 143: ... 170 MVC FD97 9 929 887 32 2001F0500 1 2001 6 Published by PV Customer Center Sony EMCS Co Kohda TEC ...