5-24
12. Auto White Balance Adjustment
Adjust to the proper auto white balance output data.
If it is not correct, auto white balance and color reproducibility
will be poor.
Mode
CAMERA
Subject
Clear chart
(Color reproduction adjustment
frame)
Filter
Filter C14 for color temperature
correction
Measurement Point
Displayed data of page: 1 (Note 3)
Measuring Instrument
Adjusting remote commander
Adjustment Page
F
Adjustment Address
3F, 40, 80
Specified Value
R ratio: 2760 to 28A0
B ratio: 5DE0 to 5F20
Note 1:
Perform “Auto White Balance Standard Data Input” be-
fore this adjustment.
Note 2:
Check that the data of page: 6, address: 02 is “00”.
If not, turn the power of unit OFF/ON.
Note 3:
The right 4 digits of the page: 1 displayed data of the
adjusting remote commander.
1:XX:XX
Displayed data
Note 4:
“Auto White Balance Adjustment” is available only once
after the power is turned on. Turn the power off, then on
again if the adjustment is retried.
Adjusting method:
Order Page Address Data
Procedure
1
Place the C14 filter on
the lens.
2
0
01
01
3
5
F1
FF
4
D
63
40
Press PAUSE button.
Perform “Data setting during
5
camera system adjustment”.
(Refer to page 5-14)
6
6
01
A7
Press PAUSE button.
49
7
F
4A
Note down the data.
4B
4C
49
28
8
F
4A
00
Press PAUSE button.
4B
5E
4C
80
9
6
01
A5
Press PAUSE button. (Note 5)
10
6
02
Check the data changes to
“01”.
11
6
01
3F
Press PAUSE button.
12
0
03
04
Order Page Address Data
Procedure
Check that the displayed data
13
1
(Note 3) satisfied the R ratio
specified value.
14
0
03
05
Check that the displayed data
15
1
(Note 3) satisfied the B ratio
specified value.
Note 5:
The adjustment data will be automatically input to page:
F, address: 3F, 40 and 80.
Processing after Completing Adjustment:
Order Page Address Data
Procedure
1
0
03
00
2
6
01
00
Press PAUSE button.
49
Set the data noted down at
3
F
4A
step 7, and press PAUSE
4B
button.
4C
4
5
F1
00
5
D
63
00
Press PAUSE button.
Release the data setting
6
performed at step 5.
(Refer to page 5-14)
7
0
01
00
Содержание FD Mavica MVC-FD97
Страница 97: ...5 29 R Y B Y 4 mm 4 mm Fig 5 1 19 A Fig 5 1 19 B R Y B Y 1 mm 1 mm 6 mm 6 mm ...
Страница 103: ...5 35 H t1 µsec Falling edge of waveform when data is 08 Falling edge of waveform when data is 09 Fig 5 1 21 ...
Страница 143: ... 170 MVC FD97 9 929 887 32 2001F0500 1 2001 6 Published by PV Customer Center Sony EMCS Co Kohda TEC ...