5-13
A
H
2.
Video Burst Level Adjustment
Adjust the burst level of the composite video signal output.
Mode
PLAY
Signal
Arbitrary
Measurement Point
Video terminal of A/V OUT jack
(75
Ω
terminated)
Measuring Instrument
Oscilloscope
Adjustment Page
F
Adjustment Address
66
Specified Value
A = 286
±
10 mVp-p (NTSC)
A = 300
±
12 mVp-p (PAL)
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
2
5
F1
04
3
F
66
Change the data and set the
burst level (A) to the
specified value.
4
Press PAUSE button
Processing after Completing Adjustments:
Order Page Address Data
Procedure
1
5
F1
00
2
0
01
00
A
H
Fig. 5-1-11
Fig. 5-1-12
1-3.
VIDEO SYSTEM ADJUSTMENTS
1.
Video Sync Level Adjustment
Adjust the sync level of the composite video signal output.
Mode
PLAY
Signal
Arbitrary
Measurement Point
Video terminal of A/V OUT jack
(75
Ω
terminated)
Measuring Instrument
Oscilloscope
Adjustment Page
F
Adjustment Address
81
Specified Value
A = 286
±
5 mVp-p (NTSC)
A = 300
±
6 mVp-p (PAL)
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
2
5
F1
04
Change the data and set the
3
F
81
sync level (A) to the specified
value.
4
Press PAUSE button
Processing after Completing Adjustments:
Order Page Address Data
Procedure
1
5
F1
00
2
0
01
00
Содержание FD Mavica MVC-FD97