5-32
18. CCD Black Defect Compensation
Mode
CAMERA
Subject
Clear chart
(25 cm from the front of lens)
Measurement Point
Displayed data of page: 6,
address: 55
Measuring Instrument
Adjusting remote commander
Adjustment Page
7
Adjustment Address
60 to 87
Note 1:
Check that there are no dust, no dirt and reflection of the
clear chart.
Note 2:
Any subject other than the clear chart should be in the
screen.
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
2
5
F1
FF
3
D
63
40
Press PAUSE button.
4
Perform “Data setting during
camera system adjustment”.
(Refer to page 5-14)
5
F
DF
Note down the data.
6
F
DF
4C
Press PAUSE button.
7
6
2C
01
8
6
90
00
9
6
91
03
10
6
92
00
11
6
93
00
12
6
6C
01
13
6
01
79
Press PAUSE button.
14
6
30
01
15
Wait for 4 seconds.
16
6
01
8D
Press PAUSE button. (Note 3)
17
6
02
Check the data changes to “01”.
18
6
55
Check the data.
00 to 0A : Normal
0B to FF : Defective
19
6
01
00
Press PAUSE button.
20
F
DF
5A
Press PAUSE button.
21
6
01
89
Press PAUSE button.
22
6
02
Check the data changes to “01”.
23
6
55
Check the data.
00: Normal
01 to FF: Defective
Note 3:
The adjustment data will be automatically input to page:
7, address: 60 to 87.
Processing after Completing Adjustment:
Order Page Address Data
Procedure
1
F
DF
Set data noted down at step
5, and press PAUSE button.
2
6
01
00
Press PAUSE button.
3
6
2C
00
4
6
30
00
5
6
6C
00
6
6
91
00
7
5
F1
00
8
D
63
00
Press PAUSE button.
9
Release the data setting
performed at step 4.
(Refer to page 5-14)
10
0
01
00