5-22
9.
Mixed Color Cancel Adjustment
To perform mixed color cancel adjustment based on data of each
color in color bar.
Mode
CAMERA
Subject
Color bar chart
(Color reproduction adjustment
frame)
Adjustment Page
F
Adjustment Address
A0 to A3
Note 1:
Perform “Light Level Adjustment” before this
adjustment.
Note 2:
Perform “Auto White Balance Standard Data Input”
after this adjustment.
Note 3:
Check that the data of page: 6, address: 02 is “00”.
If not, turn the power of the unit OFF/ON.
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
2
5
F1
FF
3
D
63
40
Press PAUSE button.
4
Perform “Data setting during
camera system adjustment”.
(Refer to page 5-14)
5
6
01
D7
Press PAUSE button.
6
6
01
D5
Press PAUSE button. (Note
4)
7
6
02
Check the data changes to “01”.
Note 4:
The adjustment data will be automatically input to
page: F, address: A0 to A3.
Processing after Completing Adjustment:
Order Page Address Data
Procedure
1
6
01
00
Press PAUSE button.
2
5
F1
00
3
D
63
00
Press PAUSE button.
4
Release the data setting
performed at step 4.
(Refer to page 5-14)
5
0
01
00
10. Auto White Balance Standard Data Input
Adjust the white balance standard data at 3200K.
Mode
CAMERA
Subject
Clear chart
(Color reproduction adjustment
frame)
Adjustment Page
F
Adjustment Address
3A to 3D, 59
Note 1:
Perform “Light Level Adjustment” and “Mixed Color
Cancel Adjustment” before this adjustment.
Note 2:
Check that the data of page: 6, address: 02 is “00”.
If not, turn the power of unit OFF/ON.
Note 3:
“Auto White Balance Standard Data Input” is available
only once after the power is turned on. Turn the power
off, then on again if the adjustment is retried.
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
2
5
F1
FF
3
D
63
40
Press PAUSE button.
Perform “Data setting during
4
camera system adjustment”.
(Refer to page 5-14)
5
6
01
11
Press PAUSE button.
6
6
01
0B
Press PAUSE button. (Note 4)
7
6
02
Check the data changes to
“01”.
Note 4:
The adjustment data will be automatically input to page:
F, address: 3A to 3D and 59.
Processing after Completing Adjustment:
Order Page Address Data
Procedure
1
6
01
00
Press PAUSE button.
2
5
F1
00
3
D
63
00
Press PAUSE button.
Release the data setting
4
performed at step 4.
(Refer to page 5-14)
5
0
01
00
6
Perform “Auto White
Balance Adjustment”.
Содержание FD Mavica MVC-FD97
Страница 97: ...5 29 R Y B Y 4 mm 4 mm Fig 5 1 19 A Fig 5 1 19 B R Y B Y 1 mm 1 mm 6 mm 6 mm ...
Страница 103: ...5 35 H t1 µsec Falling edge of waveform when data is 08 Falling edge of waveform when data is 09 Fig 5 1 21 ...
Страница 143: ... 170 MVC FD97 9 929 887 32 2001F0500 1 2001 6 Published by PV Customer Center Sony EMCS Co Kohda TEC ...