5-50
4.
Eye Sensor Check
Mode
CAMERA
Subject
White chart (30 cm
×
30 cm)
Measurement Point
Displayed data of page: 2,
address: 41
Measuring Instrument
Adjusting remote commamder
Checking method:
Order Page Address Data
Procedure
1
0
01
01
2
Set the white chart. (15 cm from
the front of the EVF)
3
2
41
Check the data changes to “00”.
4
Set the white chart. (8 cm from
the front of the EVF)
5
2
41
Check the data changes to “04”.
Processing after Completing Adjustments:
Order Page Address Data
Procedure
1
0
01
00
5.
Alignment Check (FDD Unit)
Confirm that the FDD alignment is within the specifications. If
deviated, reading and writing data from and to floppy disk be-
come impossible.
Or compatibility of floppy disk with other machines can be lost.
Mode
PLAY
Signal
Alignment disks (TFD2-1 (+))
and (TFD2-2 (–)):
Arbitrary signal
Measurement Point
Check on LCD screen
Measuring Instrument
Specified Value
The playback pictures should be
normal
Checking method:
1) Disconnect the adjusting remote commander.
2) Insert the alignment disk TFD2-1 (+) (+17.5 um).
3) Playback arbitrary signal and check that the playback picture
is normal.
4) Insert the alignment disk TFD2-2 (–) (–17.5 um).
5) Playback arbitrary signal and check that the playback picture
is normal.