5-45
5. Contrast Adjustment (FC-85 Board)
Set the level of the VIDEO signal for driving the LCD to the speci-
fied value.
If deviated, the LCD screen image will be blackish or saturated
(whitish).
Mode
PLAY
Signal
Arbitrary
Measurement Point
Pin
9
of CN803 (VG)
External trigger: Pin
8
of CN803
(COM)
Measuring Instrument
Oscilloscope
Adjustment Page
D
Adjustment Address
D4
Specified Value
A = 3.17
±
0.07 Vp-p (TYPE S)
A = 2.35
±
0.07 Vp-p (TYPE C)
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
2
5
F1
03
3
D
D4
Change the data and set the
voltage (A) to the specified value.
4
D
D4
Press PAUSE button.
Processing after Completing Adjustment:
Order Page Address Data
Procedure
1
5
F1
00
2
0
01
00
4. Bright Adjustment (FC-85 Board)
Set the level of the VIDEO signal for driving the LCD to the speci-
fied value.
If deviated, the LCD screen image will be blackish or saturated
(whitish).
Mode
PLAY
Signal
Arbitrary
Measurement Point
Pin
9
of CN803 (VG)
External trigger: Pin
8
of CN803
(COM)
Measuring Instrument
Oscilloscope
Adjustment Page
D
Adjustment Address
D0
Specified Value
A = 2.15
±
0.05 Vp-p (TYPE S)
A = 1.28
±
0.05 Vp-p (TYPE C)
Fig. 5-1-30
Fig. 5-1-31
A
2H
GAMMA1 limiter level
Pedestal
A: Between the pedestal and GAMMA1
limiter level
A
2H
10 steps peak
Pedestal
A: Between the pedestal and 10 steps peak
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
2
2
10
01
3
5
F1
03
4
D
D0
Change the data and set the
voltage (A) to the specified value.
5
D
D0
Press PAUSE button.
Processing after Completing Adjustment:
Order Page Address Data
Procedure
1
5
F1
00
2
2
10
00
3
0
01
00
Содержание FD Mavica MVC-FD97
Страница 97: ...5 29 R Y B Y 4 mm 4 mm Fig 5 1 19 A Fig 5 1 19 B R Y B Y 1 mm 1 mm 6 mm 6 mm ...
Страница 103: ...5 35 H t1 µsec Falling edge of waveform when data is 08 Falling edge of waveform when data is 09 Fig 5 1 21 ...
Страница 143: ... 170 MVC FD97 9 929 887 32 2001F0500 1 2001 6 Published by PV Customer Center Sony EMCS Co Kohda TEC ...