5-49
2.
ZOOM Center Adjustment
Set normal position (center value) of ZOOM lever.
Mode
CAMERA
Subject
Arbitrary
Measurement Point
Displayed data of page: 2
address: 5C (Note 2)
Measuring Instrument
Adjusting remote commander
Adjustment Page
D
Adjustment Address
89
Note 1:
Before adjustment, make sure that the ZOOM lever is in
mechanical center position.
Note 2:
Displayed data of page: 2, address: 5C of the adjusting
remote commander.
2:XX:5C
Displayed data
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
2
2
5C
Read the data and this data is
named Dref.
3
2
5C
Check the data.
5D to 99: Normal
00 to 5C and 9A to FF:
Defective
4
D
89
D
89
Press PAUSE button.
(See table below)
Processing after Completing Adjustments:
Order Page Address Data
Procedure
1
0
01
00
Dref
D
89
5D to 6B
6C
6C to 8A
Dref
8B to 99
8A
3.
Eye Sensor Adjustment
Mode
CAMERA
Subject
White chart (30 cm
×
30 cm)
Measurement Point
Displayed data of page: 2,
address: 82
Measuring Instrument
Adjusting remote commamder
Adjustment Page
D
Adjustment Address
EC
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
2
Set the white chart. (10 cm from
the front of the EVF)
3
2
82
Read the data and this data is
named Dref.
4
Convert Dref to decimal notation
and obtain Dref’. (Note)
5
Calculate using following equations
(decimal calculation).
D
EC
’= Dref’ – 16
6
Convert D
EC
’ to a hexadecimal
number, and obtain D
EC
. (Note)
7
D
EC
D
EC
Press PAUSE button.
Note:
Refer to table 5-2-2 “Hexadecimal-decimal conversion
table”.
Processing after Completing Adjustments:
Order Page Address Data
Procedure
1
0
01
00