5-40
4. Contrast Adjustment (VF-141 board)
Set the level of the VIDEO signal for driving the LCD to the speci-
fied value. If deviated, the screen image will be blackish or satu-
rated (whitish).
Mode
CAMERA
Subject
Arbitrary
Measurement Point
Pin
wa
of CN803 (EVF_VG) on
FC-85 board
Measuring Instrument
Oscilloscope
Adjustment Page
D
Adjustment Address
CA (NTSC)
CC (PAL )
Specified Value
A = 2.12
±
0.1 Vp-p
Menu setting:
1) VIDEO OUT of SET UP menu
.................................. NTSC (NTSC mode)
(This adjustment must be performed in NTSC mode, so don’t
set the menu setting to “PAL” )
Adjusting method (NTSC):
Order Page Address Data
Procedure
1
0
01
01
2
5
F1
03
3
D
CA
Change the data and set the
voltage (A) to the specified value.
4
D
CA
Press PAUSE button.
Adjusting method (PAL):
Order Page Address Data
Procedure
1
0
01
01
2
5
F1
03
3
D
CA
Change the data and set the
voltage (A) to the specified value.
4
D
CA
Read the data and this data is
named D
CA
.
5
Convert Dref to decimal notation
and obtain D
CA
’. (Note)
6
Calculate using following equations
(decimal calculation).
D
CA
’= D
ref
’– 4
7
Convert D
CA
’ to a hexadecimal
number, and obtain D
CA
. (Note)
8
D
CC
D
CA
Press PAUSE button.
Note:
Refer to table 5-2-2. “Hexadecimal-decimal conversion
table”.
Processing after Completing Adjustment:
Order Page Address Data
Procedure
1
5
F1
00
2
0
01
00
Fig. 5-1-27
2H
A
Pedestal
10 steps peak
A: Between the pedestal and 10 steps peak
Содержание FD Mavica MVC-FD97
Страница 97: ...5 29 R Y B Y 4 mm 4 mm Fig 5 1 19 A Fig 5 1 19 B R Y B Y 1 mm 1 mm 6 mm 6 mm ...
Страница 103: ...5 35 H t1 µsec Falling edge of waveform when data is 08 Falling edge of waveform when data is 09 Fig 5 1 21 ...
Страница 143: ... 170 MVC FD97 9 929 887 32 2001F0500 1 2001 6 Published by PV Customer Center Sony EMCS Co Kohda TEC ...